Summary of Contents for GRASS VALLEY Kudos Pro-IP-LC Series
Page 1
KUDOS PRO IP STANDARDS CONVERTERS WITH IP INTERFACE Kudos Pro-IP-LC Kudos Pro-IP-MC Kudos Pro-IP-SV User Manual IP Interface Supplement Issue 2 Revision 1 1/ 1/ ,01,12...
Grass Valley. A Grass Valley manual may have been revised to reflect changes made to the product during its manufacturing life. Thus, different versions of a manual may exist for any given product. Care should be taken to ensure that one obtains the proper manual version for a specific product serial number.
Use anti-static procedures, equipment and surfaces during servicing. The presence of this symbol in or on Grass Valley equipment means that it has been tested and certified as complying with applicable Underwriters Laboratory (UL) regulations and recommendations for USA.
Page 4
Notices The presence of this symbol in or on Grass Valley product means that it complies with all applicable European Union (CE) directives. The presence of this symbol in or on Grass Valley product means that it complies with safety of laser product applicable standards.
Page 5
Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. Before disposing of your Grass Valley equipment, please review the Disposal and Recycling Information at: http://www.grassvalley.com/assets/media/5692/Take-Back_Instructions.pdf...
Page 6
Notices Mesures de sécurité et avis importants La présente section fournit des consignes de sécurité importantes pour les opérateurs et le personnel de service. Des avertissements ou mises en garde spécifiques figurent dans le manuel, dans les sections où ils s’appliquent. Prenez le temps de bien lire les consignes et assurez-vous de les respecter, en particulier celles qui sont destinées à...
Page 7
électrique, de compatibilité électromagnétique et de conformité environnementale. Le symbole ci-contre sur un appareil Grass Valley ou à l’intérieur de l’appareil indique qu’il est conforme aux normes applicables en matière de sécurité laser. Avertissements Les avertissements signalent des conditions ou des pratiques susceptibles d’occasionner des blessures graves, voire fatales.
Page 8
Notices • Les produits qui n'ont pas d’interrupteur marche-arrêt et qui disposent d’une source d’alimentation externe doivent être installés à proximité d'une prise de courant facile d’accès. • Si l’équipement n’est pas pourvu d’un modules d’alimentation auto-adaptables, vérifiez la configuration de chacun des modules d'alimentation avant de les mettre sous tension. •...
Page 9
Kudos Pro IP User Manual IP Interface Supplement Précautions pour les écrans LCD et TFT Regarder l’écran pendant une trop longue période de temps peut nuire à votre vision. Prenez une pause de 10 minutes, après 30 minutes d’utilisation. Si l'écran LCD ou TFT est brisé, manipulez les fragments de verre avec précaution au moment de vous en débarrasser.
Grass Valley believes this environmental information to be correct but cannot guarantee its completeness or accuracy since it is based on data received from sources outside our company. All specifications are subject to change without notice.
Lithium Batteries Battery Warning Your Grass Valley equipment usually comes with at least one button battery located on the main printed circuit board. The batteries are used for backup and should not need to be replaced during the lifetime of the equipment.
Notices Laser Safety - Fiber Output SFP and QSFP Modules Warning LASER SAFETY The average optical output power does not exceed 0 dBm (1mW) under normal operating conditions. Unused optical outputs should be covered to prevent direct exposure to the laser beam.
Page 13
EMC Performance of Cables and Connectors Grass Valley products are designed to meet or exceed the requirements of the appropriate European EMC standards. In order to achieve this performance in real installations it is essential to use cables and connectors with good EMC characteristics.
Introduction Kudos Pro MC2000, LC4000 and SV4000 standards converters are available with a factory-fitted IQMIX10KP IP interface card on board, allowing for easy deployment in IP or SDI/IP environments. This supplement details the capabilities, setup and use of the IP interface, and should be used in conjunction with the user manual supplied with the converter.
Introduction Order Codes Order Codes The following product order codes are covered by this manual: Kudos Pro-IP-LC Quad-channel Linear Motion Adaptive Standards Converter with IP Interfacing. Kudos Pro-IP-MC Dual-channel Motion Compensated Standards Converter with IP Interfacing. Kudos Pro-IP-SV Quad-channel Linear Motion Adaptive Format Converter and Synchronizer with IP Interfacing.
Technical Specifications Inputs/Outputs Signal Inputs Inputs Up to 12 (0/4/8/12) Connector/Format HD-BNC/75R panel jack on standard connector panel Conforms to 3G-SDI to SMPTE 424M/425M level A compatible HD-SDI to SMPTE292M/274M/296M SD-SDI to SMPTE259M-C Input cable length Belden 1694A @ 3 Gbit/s - 80m Belden 1694A @ 1.5 Gbit/s - 140m...
Page 20
Technical Specifications RollCall Features Status Input and Output status User memories None Communication RollCall/RollCall+ Via gateway or directly via rear SFP Indicators Front Panel and Card Edge Power OK (Green) OK (Green flashing) 1-12 Input standard UHD (Green) detection LEDs 3G (Green)...
Connections This section describes the physical input and output connections provided by the IQMIX10KP. SDI BNC Input/Outputs 10 x 3G/HD/SD-SDI interfaces provided with HD-BNC. 10G Ethernet SFP SFP+ supporting 10G Ethernet. SFP Link LED Indicators SFP/QSFP LEDs indicate the following: •...
Card Edge LEDs The LEDs on the edge of the module indicate its operating status. Card Edge LEDs Front Edge Description STATUS PB=IDENT STATUS Green = PTP-LOCK OK Off = PTP-LOCK Fail BOARD BOARD Green flashing= PTP-SYNC OK Off = PTP-SYNC Fail REF ...
RollCall Control Panel This section contains information on using the IQMIX10KP IP interface module with RollCall. For help with general use of the RollCall application, open the user manual by clicking the button on the main RollCall toolbar. Terminology Term Description Essence A general term used to describe an SDI component;...
RollCall Control Panel Navigating Pages in the RollCall Template • NMOS - see page • Ethernet Pages 1 and 2 - see page • Ethernet 1 and 2 RTP Sender - see page • Ethernet 1 and 2 RTP Receiver - see page •...
Kudos Pro IP User Manual Information Display The Information display pane appears at the top of each page, and shows basic information on the input, standard and status of the module. The information to be displayed is defined on the SDI Selection and Information Select panes to the right of the Information display. Information and Selection Panes Selecting the Information to Display •...
RollCall Control Panel Configuration Configuration The Configuration page allows basic module parameters to be set. Configuration page The following facilities are available from this page: Option Description SDI IO Displays how input and output spigots are currently configured. See Card Firmware/Software Version, below, for information on how to change this.
Kudos Pro IP User Manual Option Description Domain RollCall+ uses domains to partition a network; only nodes on the same domain can communicate with one another. A domain is uniquely identified with a number and a friendly name/alias. Set an ID as required, then press Take to confirm the change. Interface Configuration Displays the IP address for each Ethernet interface.
RollCall Control Panel Time Sync Configuration Time Sync Configuration The Time Sync Configuration page allows selection of the source to be used for synchronizing flows, and configuration of any properties associated with the relevant source. Time Sync Configuration page The following facilities are available from this page: Option Description Time Sync Mode...
Kudos Pro IP User Manual Option Description PTP Configuration Select values from the PTP Domain and PTP Delay Request Frequency drop-down lists, as required. Type the appropriate IP number into the PTP Multicast address field. PTP Status Displays PTP status information. Enable the Details check box to display detailed interface status information, reset counters, show details for other PTP interfaces etc.
Page 32
RollCall Control Panel Time Sync Configuration Interface Status Details Item Description Last Lock Time when PTP last locked. Lost Lock Time when PTP last lost lock. 1 Step syncs Increments on reception of Sync message that has the =false. twoStepFlag 2 Step Syncs Increments on reception of Sync message that has the =true.
Page 33
Kudos Pro IP User Manual Item Description Request Interval Return actual minimum interval between delay request messages. This is as set in the PTP Delay Request Frequency control. See Configuration on page 28. Values are, {256/s, 128/s, 64/s, 32/s, 16/s, 8/s, 4/s, 2/s, 1s, 2s, 4s, 8s, 16s}.
Page 34
RollCall Control Panel Time Sync Configuration Histogram pane Visible Clocks Displays the GrandMaster clocks present on the network. Visible Clocks pane...
Kudos Pro IP User Manual Sender TPG (Test Pattern Generator) The Sender TPG page allows test patterns to be applied to senders on a spigot-by-spigot basis. page Sender TPG The following options are available for each spigot: Option Operation Select the test pattern to apply to the spigot from the drop-down list.
RollCall Control Panel Receiver TPG (Test Pattern Generator) Receiver TPG (Test Pattern Generator) The Receiver TPG page allows test patterns to be applied to receivers on a spigot-by-spigot basis. page Receiver TPG The following options are available for each spigot: Option Operation TPG Enable...
Kudos Pro IP User Manual Counters The Counters page allows the various counters provided to be cleared down. Counters page Click Clear buttons as required.
RollCall Control Panel NMOS NMOS The NMOS page allows NMOS functionality to be configured. NMOS page Overview Networked Media Open Specifications, collectively known as NMOS, have been developed to provide interoperability between a wide range of products from various manufacturers. NMOS effectively provides a control and management layer in addition to the transport layer provided by SMPTE ST2110.
Page 39
Kudos Pro IP User Manual Option Description IS-04 Controls how the module is to find and use network resources. Set as required. • Status - displays registration status of the module. Valid values are: • Not Registered • Registering • Registered •...
RollCall Control Panel Ethernet Pages 1 and 2 Ethernet Pages 1 and 2 Note: Ethernet pages 1 & 2 refer to the rear-panel Ethernet connectors only. See Ethernet Gb on page 79 for information on managing the on-module Ethernet connector. The Ethernet pages show details and status for each network interface.
Kudos Pro IP User Manual Ethernet 1 and 2 RTP Sender The RTP Sender page displays the amount of data transmitted, on a spigot-by-spigot basis. Units are megabits per second. Click Enable Stats to display values. Ethernet 1 & 2 RTP Sender page...
RollCall Control Panel Ethernet 1 and 2 RTP Receiver Ethernet 1 and 2 RTP Receiver The RTP Receiver pages display the amount of data received, plus details of packet loss, on a spigot-by-spigot basis. Units are megabits per second. Click Enable Stats to display values; click Clear RTP Count or Clear Error Count to zero RTP Sequence Discontinuity or Error counters.
Kudos Pro IP User Manual Ethernet RTP Receiver Video Stats The Ethernet RTP Receiver Video Stats page displays information on the data received via RTP on each Ethernet input. Units are megabits per second. Click Enable Stats to display values; click Clear All RTP Counts to zero RTP Discontinuity counters for each Ethernet input.
RollCall Control Panel Ethernet RTP Receiver Audio Stats Ethernet RTP Receiver Audio Stats The Ethernet RTP Receiver Audio Stats page displays information on the data received via RTP on each Ethernet input. Units are megabits per second. Click Enable Stats to display values; click Clear All RTP Counts to zero RTP Discontinuity counters for each Ethernet input.
Kudos Pro IP User Manual Ethernet RTP Receiver Meta Stats The Ethernet RTP Receiver Meta Stats page displays information on the metadata received via RTP on each Ethernet input. Units are megabits per second. Click Enable Stats to display values; click Clear All RTP Counts to zero RTP Discontinuity counters for each Ethernet input.
RollCall Control Panel Link Control Link Control The Link Control page allows 4K spigots to be configured. Input/output can be via single or quad link. See Configuration on page 28 for information on selecting the required input/ output configuration. Link Control page UHD Links Enable the spigots to be used as required.
Kudos Pro IP User Manual HDR Control The HDR Control page allows outgoing SDI traffic to be modified to indicate that it contains HDR content. HDR Control page A New pane is displayed against output spigots. Select options from the drop-down menus for each spigot as required, then click Take to apply the changes.
Page 48
RollCall Control Panel HDR Control Option Description Color Space Available values are: • YCbCr • ICtCp • Other Bit Depth Available values are: • 10bit • 10bit Full range...
Kudos Pro IP User Manual Destination Timing The Destination Timing page allows genlock timing on each spigot to be adjusted, in order to synchronize the IP signal with the house reference. Destination Timing page The following parameters can be modified: Option Description Genlock Timing V Offset...
RollCall Control Panel Audio V Fade Audio V Fade This page allows audio fading to be applied on a spigot-by-spigot basis, in order to minimize audio disruption. When applied, the audio will fade down on input loss and perform an audio V fade (down then up) during input switching.
Kudos Pro IP User Manual Audio Type Control The Audio Type Control page allows audio pairs to be marked as carrying PCM or non-PCM. Only pairs on IP receiver spigots are displayed. Audio Type Control page Enable check boxes for pairs carrying PCM.
RollCall Control Panel Input Loss Control Input Loss Control The Input Loss Control page allows control of the module’s response to signal loss. Select as required. Input Loss Control page Options upon signal loss are: Option Operation Freeze Picture will freeze. Black Picture will cut to black.
Kudos Pro IP User Manual Spigot Pages A separate page is provided for each of the active spigots. These pages are dynamically configured by the product, based on the capabilities of the software version/firmware selected. Note: The pages shown here may differ from those seen on your particular system, depending on the model and configuration of your IQUCP module.
Page 54
RollCall Control Panel Input Spigots Option Operation Spigot Pane Displays spigot direction, associated BNC connector, current module status, the last Take performed on the spigot and how it was made, e.g. via RollCall or an external agent such as VSM. The following controls are also available: •...
Page 55
Kudos Pro IP User Manual Option Operation Flow Panes (Primary, Displays Video, Audio and Metadata status, and allows Secondary, Audio and multicast IP and port details to be defined for the selected Metadata) spigot. To set multicast details for the spigot: •...
RollCall Control Panel Output Spigots Output Spigots Output spigots are defined by selecting the appropriate firmware version on the Configuration page. See Configuration on page 28 for more information. Typical Output Spigot page Spigot Pane The Spigot pane provides basic monitoring for the selected Spigot. Click Take to apply any changes made.
Kudos Pro IP User Manual The Spigot pane details: • Spigot direction; • Associated BNC connector; • Current status; • The last Take performed on the spigot. Streaming Select the Ethernet connectors to use for this spigot. This will also determine the bandwidth to be used.
Page 58
RollCall Control Panel Output Spigots Output Spigot Flow Pane Setting Multicast Details To set multicast details: • Select the required video standard from the drop-down list. • Enter multicast IP and port details as required. • Enter the appropriate details in the Source IP and Source Port fields. Each spigot can support a variety of flows.
Kudos Pro IP User Manual Logging SDI Info Information on various parameters can be made available to a logging device connected to the RollCall network. Each logging page comprises three columns: • Log Enable - Select the check boxes that correspond to the parameters for which log information should be collected.
RollCall Control Panel Logging - System Logging - System Information on several parameters can be made available to a logging device connected to the RollCall network. Each logging page comprises three columns: • Log Enable - Select the check boxes that correspond to the parameters for which log information should be collected.
Page 61
Kudos Pro IP User Manual The following logging options are available. Enable check boxes to activate log fields as required. Log Field Description Reports the module serial number, which consists of an S followed by eight digits. Note: this cannot be deselected. OS_VERSION= Reports the operating system name and version.
Page 62
RollCall Control Panel Logging - System Log Field Description TIMESYNC_N_MODE= Valid values are: • Free running: Module is using its own clock with no reference to any other source. • PTP Multicast: Card is synchronizing to a PTP grandmaster clock using multicast network messages. •...
Page 63
Kudos Pro IP User Manual Log Field Description TIMESYNC_N_LAST_ Time when the module last changed from not locked to LOCK= locked. Ideally this will be a few seconds after the module has powered up. This allows the user to confirm which clock the module has synchronized to.
RollCall Control Panel Logging - Network Logging - Network Information on several parameters can be made available to a logging device connected to the RollCall network. Each logging page comprises three columns: • Log Enable - Select the check boxes that correspond to the parameters for which log information should be collected.
Page 65
Kudos Pro IP User Manual The following logging options are available. Enable check boxes to activate log fields as required. Log Field Description LAN_PORT_N_NAME= Logs the Ethernet port name. LAN_PORT_N_SPEED= Logs the Ethernet connection speed. Valid values are: • 10 Mbit/s Full Duplex •...
Page 66
RollCall Control Panel Logging - Network Log Field Description LAN_PORT_N_SWITCH_NAME= Logs name of the network switch that the module is connected to. LAN_PORT_N_SWITCH_CHASSIS Logs the MAC address of the switch port to which the _ID= module’s media port is connected. LAN_PORT_N_SWITCH_PORT_...
Kudos Pro IP User Manual Logging - SFP Information on several parameters can be made available to a logging device connected to the RollCall network. Each logging page comprises three columns: • Log Enable - Select the check boxes that correspond to the parameters for which log information should be collected.
Page 68
RollCall Control Panel Logging - SFP Log Field Description SFP_N_FITTED= Logs presence of (Q)SFP. Valid values are: • OK • Missing SFP_N_STATUS= Logs status reported by the (Q)SFP. Valid values are: SFPs • OK • WARN:Temp • WARN:VCC • WARN:TX BIAS •...
Page 69
Kudos Pro IP User Manual Log Field Description SFP_N_SERIAL_NR= Logs the module serial number, which consists of an S followed by eight digits. SFP_N_REVISION= Logs manufacturer revision number. SFP_N_CONNECTOR= Logs connector type. TEMP_N_NAME= Logs temperature sensor name. TEMP_N_CELSIUS= Logs current temperature sensor reading. TEMP_N_STATE= Logs temperature sensor state.
RollCall Control Panel Logging - FPGA Logging - FPGA Information on several parameters can be made available to a logging device connected to the RollCall network. Each logging page comprises three columns: • Log Enable - Select the check boxes that correspond to the parameters for which log information should be collected.
Kudos Pro IP User Manual Logging - Spigot The Logging - Spigot pages are used to select the fields to be enabled for each available spigot. Depending on whether the spigot is an input or an output, the appropriate log fields are shown.
Page 72
RollCall Control Panel Logging - Spigot Option Description INPUT_N_STATE= Valid values are: • OK: input signal good. • FAIL: input signal not detected. INPUT_N_TYPE= HD/SD/3G SDI INPUT_N_STANDARD= PAL/NTSC/625 Mono/525 Mono INPUT_N_STREAM= Displays whether an IP sender uses SDI on Primary, Secondary or both.
Kudos Pro IP User Manual Logging - NMOS Information on several NMOS parameters can be made available to a logging device connected to the RollCall network. Each logging page comprises three columns: • Log Enable - Select the check boxes that correspond to the parameters for which log information should be collected.
RollCall Control Panel Logging - Card Diagnostics Logging - Card Diagnostics Information on several parameters can be made available to a logging device connected to the RollCall network. Each logging page comprises three columns: • Log Enable - Select the check boxes that correspond to the parameters for which log information should be collected.
Kudos Pro IP User Manual RollTrack The RollTrack page allows information to be sent, via the RollCall network, to other compatible units connected on the same network. The Source window lists the RollTrack sources: Source Pane Disable All When checked, all RollTrack items are disabled. RollTrack Index This slider allows up to 16 distinct RollTrack outputs to be set up.
RollCall Control Panel RollTrack • The third set, 01, is the slot number in the unit. • The fourth set, 99, is a user-definable number that is a unique identifier for the destination unit in a multi-unit system. This ensures only the correct unit will respond to the command. If left at 00, an incorrectly fitted unit may respond inappropriately.
Kudos Pro IP User Manual Loopback Router The Loopback Router page provides a basic SDI router as a redundant backup in case of Ethernet failure. Loopback Router page If an Ethernet failure is encountered: 1 Use the matrix radio buttons to specify which inputs should be routed to which outputs. 2 Select the Video Flow to Use - SMPTE-2022, RFC4175 or VC2.
Use the functions on the page to restart the module or to return all settings to their factory or default settings. Setup page The Product pane displays technical information on the Kudos Pro IP. You may be asked for these details by Grass Valley support if you need technical assistance. Item Description Product Name of the module.
Kudos Pro IP User Manual Item Description Daughter Mod Level Daughter board PCB modification level. Daughter HW Build Factory daughter board hardware build number. Restart Power-cycles the module. This will produce disturbances on the output picture. Note: Restarting the module will affect all outputs. Defaults Provides options to reset the module to its defaults.
Kudos Pro IP User Manual Interop The Interop page allows certain parameters to be changed in order to improve interoperability with third-party equipment. Interop page The following facilities are available from the Interop page:...
Page 82
RollCall Control Panel Interop Option Description Stream Synchronization Audio: Controls • Extended Headers - Enable to use extended headers in the RTP audio stream. • RTP to PTP - Enable to synchronize RTP to PTP. • Nominal Delay - Enable to set nominal delay at the spigot.
1-800-547-8949 (US and Canada) or +1 530 478 4148. To obtain a local phone number for the support center nearest you, please consult the Contact Us section of Grass Valley’s website ( www.grassvalley.com An online form for e-mail contact is also available from the website.