Ro - Read What Output Is Connected To Nn Input; Sb - Set Serial Port Baud Rate; 10. Ss - Switch Input To Specified Output; 11. Sv - Save The Current Connections Into A Profile - ATEN VM5404D User Manual

Table of Contents

Advertisement

8. RO – Read what output is connected to nn input
RO 01
Output port 02 is connected to input port 01
9. SB – Set serial port baud rate
SB 96
Serial port baud rate is set to 9600
10. SS – Switch input to specified output
SS 01,03
Switch input 01 to output 03
11. SV – Save the current connections into a profile
SV 01
Save the current connections into profile 01
12. TI – Set timeout
TI 30
Set 30 minute timeout
13. VR – Software version information
VR
Software version 1.0.