Fitting The Outer Case - Potterton Promax 15 HE Installation And Servicing Instructions

Wall mounted powered flue condensing boiler gas firel central heating unit
Table of Contents

Advertisement

26
Supplied By www.heating spares.co Tel. 0161 620 6677

11.0 Fitting the Outer Case

11.1
1. Position the outercase over the boiler
engaging the lugs in the side flanges over the
hooks on the wall plate (Fig. 37).
2. Carefully centralise the On/Off switch through
the cut-out on the facia. Using the screw
supplied in the kit, secure the outercase from
the bottom (Fig. 37).
3. Carefully read and complete all sections of
the "Benchmark" Installation, Commissioning
and Service Record Log Book that are relevant
to the appliance and installation. The details of
the Log Book will be required in the event of any
warranty work. The Log Book must be handed
to the user for safe keeping and each
subsequent regular service visit recorded.
4. Instruct the user in the operation of the boiler
controls. Hand over the User's Operating,
Fig. 37
Installation and Servicing Instructions and the
Log Book, giving advice on the necessity of
regular servicing.
5. Advise the user that a plume of vapour from
the flue terminal is normal, and that there is no
need for concern.
IMPORTANT: This boiler is fitted with an
aluminium alloy heat exchanger.
It is important that the system is thoroughly
flushed in accordance with BS 7593 and that
one of the following inhibitors is used:
Refer to inhibitor manufacturer's instructions
for correct use. Failure to comply with this
requirement will invalidate the appliance
warranty.
It is also important to check the inhibitor
concentration after installation, system
modification and at every service.
Date Boiler Installed
Fig. 38
Inhibitor Used
6. This label is located on the electrical box front
cover on the boiler. Detail of system treatment
should be added for future reference.
Fitting The Outer Case
BETZ DEARBORN SENTINEL X100
FERNOX COPAL
/
/

Advertisement