Potterton Promax 15 HE Installation And Servicing Instructions page 39

Wall mounted powered flue condensing boiler gas firel central heating unit
Table of Contents

Advertisement

No Pump Feed
Is
YES
Safety Thermostat
open circuit ?
NO
Is
YES
Fan Protection
Thermostat
open circuit ?
NO
Is
NO
thermistor resistance
between 0.5kΩ and
20kΩ ?
YES
Is
YES
combustion box door
seal damaged or not
in place ?
NO
Is
YES
condensate trap
blocked ?
NO
Go to
IGNITION LOCKOUT
section of the fault
finding instructions.
Supplied By www.heating spares.co Tel. 0161 620 6677
Replace safety
thermostat (black)
Replace fan
protection thermostat.
Replace flow
temperature
thermistor (red)
Replace combustion
box door seal.
Clear blockage and
dry sensors.
15.0 Fault Finding
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promax 24 he

Table of Contents