Dimensions And Fixings - Potterton Promax 15 HE Installation And Servicing Instructions

Wall mounted powered flue condensing boiler gas firel central heating unit
Table of Contents

Advertisement

(1 in 20)
D
Fig. 6
X
Fig. 7
8
Supplied By www.heating spares.co Tel. 0161 620 6677
E
A
B
360° Orientation
C
Tube Ø 110mm
F
Y

5.0 Dimensions and Fixings

The 3° (1 in 20) fall provided by
the elbow is to allow condensate
to run back to the boiler, for
disposal through the condensate
discharge pipe.
SIDE FLUE (left and right)
For every 1m of horizontal flue
length, the clearance above the
top of the flue elbow should be
(1 in 20)
55mm to incorporate the 3°
(1 in 20) fall in the flue from the
terminal to the elbow.
Flue length (Y)
up to 1m
1m - 2m
2m - 3m
DIMENSIONS
A 600mm
B 320mm
C 390mm
D 125mm Ø Min.
E 150mm
F 125mm
Clearance (X)
55mm
110mm
165mm