Trouble Shooting - Pkm 8060G Instruction Manual

Extractor hood
Table of Contents

Advertisement

Available languages

Available languages

MALFUNCTION
 The appliance
does not work at
all.
 LED does not
work at all.
 Light is on but
motor does not
work
 The motor
smells doubtful
 Smear of oil
 Appliance
vibrates
 Insufficient
extracting
capacity
 Light does not
work
 Appliance is
unstable
If the hood does not work properly and/or you can hear increased operating noise, check the
 incorrect dimension of the air duct.
 obstruction in the air duct.
 the diameter of the air duct from hood to wall-box inclusive should be 150 mm;
otherwise the capacity of the motor may be decreased.
 if you have installed a fly screen on the wall-box, the air vent may be obstructed.
Check by removing the fly screen.
 if the cover panel of the wall box is equipped with firm and slanted slats, the air vent
may be obstructed. Check by removing the cover panel.
 install a cover panel with moveable slats, which do not obstruct the air vent.
 check condition and cleanliness of the filters.
 check if the air which is extracted by the hood is replaced to avoid negative pressure.
 when you run your appliance in recirculating mode, check if the carbon filter has been
replaced on time ( min. every 6 months ).

8. TROUBLE SHOOTING

POSSIBLE CAUSE
 The plug of the appliance is not
connected to the socket.
 The plug has become loose.
 The socket is not supplied with
energy.
 The fuse is switched off.
 ventilation damper blocked
condenser
defective
 motor mounting defective
 motor defective
 one-way valve is leaky
 connection base chimney-
telescopic chimney is leaky
 motor not properly fixed
 hood not properly fixed
 too much distance hood-hob
 too much draught because of
open doors and/or windows
 illuminate is defective
 mounting rail is not firmly fixed
 screws are not firmly tightened
schedule below:
88
MEASURE
 Check the
corresponding socket
by connecting it with
another appliance.
 Check the fuse.
 The voltage is too low.
Compare the data on
the model plate with
the data of your energy
supplier.
 remove blockage
 replace condenser
 replace motor
 replace motor
 seal the valve
 seal the connection
with a suitable material
 fix motor properly
 fix hood properly
 lower position of hood
 close the
doors/windows
 Contact the after sales
service.
 fix mounting rail
properly
 tighten the screws

Hide quick links: