Control Port Functions
No.
Name
72
PD16/D16/IRQ0
73
PD15/D15
74
PD14/D14
75
PD13/D13
76
PD12/D12
77
VCC
78
PD11/D11
79
VSS
80
PD10/D10
81
PD9/D9
82
PD8/D8
83
PD7/D7
84
PD6/D6
85
VCC
86
PD5/D5
87
VSS
88
PD4/D4
89
PD3/D3
90
PD2/D2
91
PD1/D1
92
PD0/D0
93
VSS
94
XTAL
95
MD3
96
EXTAL
97
MD2
98
NMI
99
VCC (FWP)
100
PA16/AH
101
PA17/WAIT
102
MD1
103
MD0
104
PLLVCC
105
PLLCAP
106
PLLVSS
107
PA15/CK
108
RES
109
PE0/TIOC0A/DREQ0
110
PE1/TIOC0B/DRAK0
111
PE2/TIOC0C/DREQ1
112
VCC
113
PE3/TIOC0D/DRAK1
114
PE4/TIOC1A
115
PE5/TIOC1B
116
PE6/TIOC2A
117
VSS
118
PF0/AN0
119
PF1/AN1
120
PF2/AN2
121
PF3/AN3
122
PF4/AN4
123
PF5/AN5
124
AVSS
125
PF6/AN6
126
PF7/AN7
127
AVREF
128
AVCC
129
VSS
130
PA0/RXD0
131
PA1/TXD0
132
PA2/SCK0/DREQ0/IRQ0
133
PA3/RXD1
134
PA4/TXD1
135
VCC
136
PA5/SCK1/DREQ1/IRQ1
137
PE7/TIOC2B
138
PE8/TIOC3A
139
PE9/TIOC3B
140
PE10/TIOC3C
141
VSS
142
PE11/TIOC3D
143
PE12/TIOC4A
144
PE13/TIOC4B/MRES
Function Name
Function
PW_SW
Not used
DATA15
Data Bus 15
DATA14
Data Bus 14
DATA13
Data Bus 13
DATA12
Data Bus 12
5V
-
DATA11
Data Bus 11
GND
-
DATA10
Data Bus 10
DATA9
Data Bus 9
DATA8
Data Bus 8
DATA7
Data Bus 7
DATA6
Data Bus 6
5V
-
DATA5
Data Bus 5
GND
-
DATA4
Data Bus 4
DATA3
Data Bus 3
DATA2
Data Bus 2
DATA1
Data Bus 1
DATA0
Data Bus 0
GND
-
XTAL
X'tal oscillator input
Mode3
Multiplex setting with Mode 2 (Set H)
EXTAL
X'tal oscillator output
Mode2
Multiplex setting with Mode 3 (Set L)
CPURESET
Non maskarable interrupt input (for manual setting)
FWP
Write mode for flash memory
FLASH MODE
FWP Control
Not used
Mode1
MCU setting with Mode 0 (Set H)
Mode0
MCU setting with Mode 1 (Set L)
PLLVCC
Power supply for PLL
PLLCAP
PLL filter
PLLGND
Ground for PLL
M-CLK
CPU clock output
RESET
Reset
ET7050SCS
ET7050 Serial chip select
OPT4
XGA/SVGA switch option
Not used
5V
-
SDA3
IIC Bus 3 SDA
SCL3
IIC Bus 3 SCL
USB_BRST
USB pull-up option resistor on-off
Not used
GND
-
KEY1
Key 1 input (A/D input)
KEY2
Key 2 input (A/D input)
KEY3
Key 3 input (A/D input)
OPT1
Destination option1 (A/D input)
OPT2
Destination option2 (A/D input)
LAMP DET
Lamp error detection
GND
Ground for A/D
POWER FAIL
Power Fail input (Error at less than 2V)
OPT3
Not used
5V
Reference voltage for A/D
5V
Power for A/D
GND
-
PW_RX
PW365 Rx
PW_TX
PW365 Tx
SEPA_INT
Interrupt input from M66230
RXD
RS232C (Control Port)Rx
SH_TXD
RS232C (Control Port)Tx
5V
-
USB INTR
USB Interrupt input
FAN SW
FAN ON/OFF switch
LAMP SW
LAMP ON/OFF output
SDATA OUT
3 Line serial data output
SCLK
3 Line serial clock output
GND
-
EXP RESET
I/O Expander(M66500FPM) reset output
R/C
remote contol input
PW RESET
PW365reset signal
-50-
Polarity
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Active L
Active L
-
-
-
-
Active L
Active L
Active L
Active L
-
Active L
Active H
-
Active H
Active L
Active L
I/O
I/O
I/O
I/O
I/O
-
I/O
-
I/O
I/O
I/O
I/O
I/O
-
I/O
-
I/O
I/O
I/O
I/O
I/O
-
I
I
O
I
I
I
O
O
I
I
-
-
-
O
I
O
I
O
-
I/O
I/O
O
O
-
I
I
I
I
I
I
-
I
I
I
I
-
I
O
I
I
O
-
I
O
O
O
O
-
O
I
O