Sanyo PLC-XT10 Service Manual page 17

Hide thumbs Also See for PLC-XT10:
Table of Contents

Advertisement

Optical Parts Disassemblies
Locations and Directions
When the optical parts in the optical unit mounting or assembling, the
parts must be mounted in the specified location and direction as
shown in figure below.
Note: The arrow in the figure below is indicated that there is the direc-
tion of part placement. Place each part as the printed marker on
the part comes to each arrow direction.
The key No. 16 should be placed as the film attached side
comes to the mirror side.
4
5
9
6
7
8
3
2
1
10
12
16
-17-
Key No. Description
1
Slit-Int
2
Integrator Lens-Out
3
PBS (Prism Beam Splitter)
4
Mirror (W-Cold)
5
Condenser lens-Out
6
Dichroic mirror (B)
7
Optical Filter (UV Cut)
8
Mirror Holder
9
Mirror (B)
10
Condenser lens
11
Dichroic Mirror (G)
12
Condenser Lens (G)
13
Relay lens-In
14
Mirror (R)
15
Condenser Lens (R)
16
Pre-polarized glass (B)
15
11
14
13
14
Fig.8