Mechanical Disassemblies
10
Power AC Board removal
1
A
Remove 4 screws
( T3x6) to take the Power Board off.
2
B
Remove 4 screws
(T3x10) to take the Holder from the
cabinet bottom.
11
Line Filter Board & Interlock SW removal
1
C
Remove 3 screws
(T3x10) to take the Filter Board
Ass'y upward.
2
D
Remove 3 screws
(T3x8) and 1 screw
take the Filter Board from the Holder.
3
F
Remove 2 screws
(T3x10) to take the Interlock switch
(SW902) from the cabinet bottom.
12
Fans (FN901, FN902) removal
1
A
Remove 1 screw
(T3x20) then take the Fan (FN906) off
B
and remove 3 screws
2
C
Remove 4 screws
(T3x10) to take the Duct-B off.
3
D
Remove 3 screws
(T3x10) to take the Duct-C off,
E
remove 1 screw
(T3x10) and 1 screw
the Sensor Board off.
4
G
Remove 2 screws
(T4x25) to take the Fan (FN902) off.
H
Remove 2 screws
(T4x25) to take the Fan (FN901) off.
5
J
Remove 2 screws
(T3x8) to take the Duct Cover off and
K
remove 2 screws
(T4x25) to take the Fan (FN903) off.
6
L
Remove 4 screws
(T3x10) to take the Duct-D off.
E
(T3x6) to
Interlock Switch
(SW902)
(T3x10) to take the Duct-A off.
F
(T3x6) to take
FN906
B
B
Duct-A
A
D
F
C
F
C
D
C
Duct-B
Duct
Cover
H
J
J
A
K
K
L
FN903
L
B
Duct-D
-12-
A
Power AC
Board
A
A
B
B
B
Power Board
Holder
Filter Board
D
E
C
C
C
C
D
Duct-C
H
FN901
G
FN902
L
L
Sensor Board
Fig.8
D
D
F
E
G
Fig.9

Advertisement

Table of Contents
loading