Electrical Adjustments
No.
Adjustment Item
16
R_BLK_DC
17
VRB
18
GVRT
19
BVRT
20
RVRT
21
R_V_COM_CEILING
22
G_V_COM_CEILING
23
B_V_COM_CEILING
24
NRSB_CEILING
25
NRSA_CEILING
Group: 6 TC90A69F
0
Y-EQ_GAIN
1
Y-EQ_N_C_LIM
2
V-ENH_GAIN
3
V_ENH_CORING
4
NTSC443_SW
Group: 10 Option
0
Lamp Time Monitor
1
RS232C Baudrate
2
Shootout Mode
3
Cooling Time
4
Hi-Land SW
5
V-Douki SW
6
Lamp Total Time
7
--
8
Keystone Option
9
Syukka SW
10
Color Shading SW
11
RC Enable/Disable
12
Lamp Dim Level
13
Lamp Warning Time
14
Forced NOBRAND
15
Forced Video Mute Off
16
Fan Control SW for Testing
Group: 11 Fan Control
0
FAN_TEMP_A_WARNING
1
FAN_TEMP_B_WARNING
2
FAN_TEMP_C_WARNING
3
FAN_TEMP_B-A_WARNING
4
FAN_TEMP_C-A_WARNING
5
FAN_CONTROL_SW
6
FAN_A_SPEED
7
FAN_B_SPEED
8
FAN_C_SPEED
9
FAN_TEMP_A_MONI
10
FAN_TEMP_B_MONI
11
FAN_TEMP_C_MONI
12
FAN_ANZEN_MINMAX
13
TEMP_NOWARNING_TIME
14
NOR_TEMP_FAN1_MIN
15
NOR_TEMP_FAN1_MAX
16
NOR_TEMP_FAN2_MIN
17
NOR_TEMP_FAN2_MAX
18
NOR_TEMP_FAN3_MIN
19
NOR_TEMP_FAN3_MAX
20
NOR_VALU_FAN1_MIN
21
NOR_VALU_FAN1_MAX
22
NOR_VALU_FAN2_MIN
23
NOR_VALU_FAN2_MAX
24
NOR_VALU_FAN3_MIN
25
NOR_VALU_FAN3_MAX
26
ECO_TEMP_FAN1_MIN
27
ECO_TEMP_FAN1_MAX
28
ECOTEMP_FAN2_MIN
29
ECO_TEMP_FAN2_MAX
30
ECO_TEMP_FAN3_MIN
31
ECO_TEMP_FAN3_MAX
32
ECO_VALU_FAN1_MIN
33
ECO_VALU_FAN1_MAX
34
ECO_VALU_FAN2_MIN
35
ECO_VALU_FAN2_MAX
36
ECO_VALU_FAN3_MIN
37
ECO_VALU_FAN3_MAX
38
HINOR_TEMP_FAN1_MIN
39
HINOR_TEMP_FAN1_MAX
40
HINOR_TEMP_FAN2_MIN
41
HINOR_TEMP_FAN2_MAX
42
HINOR_TEMP_FAN3_MIN
43
HINOR_TEMP_FAN3_MAX
44
HINOR_VALU_FAN1_MIN
45
HINOR_VALU_FAN1_MAX
Initial Value
Range
Input source / Description
80/80/80
0 ~ 255
AV Pedestal Adjustment video/1080i,1035i,720p/480p,525p
115
0 ~ 255
dac3
130
0 ~ 255
dac2
130
0 ~ 255
dac2
130
0 ~ 255
dac2
0
0 ~ 255
dac2 R-common center adjustment, deferential value at Ceiling On (0: ±0, 1: +1, 255: -1)
0
0 ~ 255
dac2 G-common center adjustment, deferential value at Ceiling On (0: ±0, 1: +1, 255: -1)
0
0 ~ 255
dac2 B-common center adjustment, deferential value at Ceiling On (0: ±0, 1: +1, 255: -1)
0
0 ~ 255
NRSB , deferential value at Ceiling On (0: ±0, 1: +1, 255: -1)
0
0 ~ 255
NRSA , deferential value at Ceiling On (0: ±0, 1: +1, 255: -1)
3
0 ~ 3
3
0 ~ 3
4
0 ~ 7
2
0 ~ 3
1
0 ~ 1
Set for input signal system 0:NTSC4.431:PAL60 (It is effective when input signal is NTSC4.43)
-
0~8738
Read only
0
0 ~ 1
0: 19200bps1: 9600bps
0
0 ~ 1
1: Shoot Out Mode Enable0: Disable
3
0 ~ 15
Cooling time setting 1:30 sec. 3:90 sec. 15:450 sec. 0:continuously On
0
0 ~ 255
0: Land mode(Normal operation) 1: High-land mode(Fan spinning in max speed)
0
0 ~ 1
0:V synchronized1:V not synchronized
-
0~65535
Read only
0
0 ~ 1
0:Fixed limitation 1:Change limitation according to input signal
0
0 ~ 10
Reset user control value when the data changes to 10 and turns to 0.
1
0 ~ 1
0:On 1:Off
0
0 ~ 3
0: Activate both Front and Rear RC 1:Prohibition-Front 2:Prohibition-Front 3:Deactivate both Front and Rear RC
0
0 ~ 10
0: Maximum (250W)10:Minimum(200W)
1000
0~65535
in hours, can not be changed
0
0 ~ 1
0:Normal 1:On
0
0 ~ 1
0:VideoMuteOn(Normal) 1:Forced VideoMuteOff
0
0 ~ 4
0: Normal, 1: Normal Min., 2: NormalMax., 3: Eco Min., 4: Eco Max. but not be memorized
47
30 ~ 100
Temperature A to judge the abnormal (Not memorized) Room
55
30 ~ 100
Temperature B to judge the abnormal (Not memorized) Panel
67
30 ~ 100
Temperature C to judge the abnormal (Not memorized)lamp
20
0 ~ 100
Temperature B-A to judge the abnormal (Not memorized) Detection of filter croggle
35
0 ~ 100
Temperature C-A to judge the abnormal (Not memorized) Detection of filter croggle
0
0 or 1
0:Fan Control automatically 1:Fan Control Manually
-
0 ~ 255
Only effective when FAN_CONTROL_SW = 1
-
0 ~ 255
Initial Normal/Eco
-
0 ~ 255
-
-
Read only
-
-
-
-
1
0 or 1
Only effective when FAN_CONTROL_SW=1, it can be used with10-12 but not be memorized.
0
0 ~ 5
Do not detect temp error within specified time after turn on.
27
FAN1 temperature to start the control, Normal
35
FAN1 temperature to end the control, Normal
27
0~255
FAN2 temperature to start the control, Normal
35
FAN2 temperature to end the control, Normal
27
FAN3 temperature to start the control, Normal
35
FAN3 temperature to end the control, Normal
60
FAN1 control minimum value, Normal( 0: Fan voltage 0V, 255:Fan voltage 25.5V)
135
FAN1 control maximum value, Normal
60
0~255
FAN2 control minimum value, Normal
135
FAN2 control maximum value, Normal
60
FAN3 control minimum value, Normal
120
FAN3 control maximum value, Normal
27
FAN1 temperature to start the control, Eco
35
FAN1 temperature to end the control, Eco
27
0~255
FAN2 temperature to start the control, Eco
35
FAN2 temperature to end the control, Eco
27
FAN3 temperature to start the control, Eco
35
FAN3 temperature to end the control, Eco
55
FAN1 control minimum value, Eco
120
FAN1 control maximum value, Eco
70
0~255
FAN2 control minimum value, Eco
100
FAN2 control maximum value, Eco
55
FAN3 control minimum value, Eco
100
FAN3 control maximum value, Eco
22
FAN1 temperature to start the control, HighLand Normal
30
FAN1 temperature to end the control, HighLand Normal22
22
0~255
FAN2 temperature to start the control, HighLand Normal
30
FAN2 temperature to end the control, HighLand Normal
22
FAN3 temperature to start the control, HighLand Normal
30
FAN3 temperature to end the control, HighLand Normal
90
FAN1 control minimum value, HighLand Normal (0: Fan voltage 0V, 255:Fan voltage 25.5V)
138
FAN1 control maximum value, HighLand Normal
-33-
A/D Ref Voltage Adjustment {BOTTOM]
A/D Ref Voltage Adjustment [TOP]
FAN Voltage Adjustment