Configuration Digit
GLOW PLUG:
5
STARTER LOCKOUT:
6
ENGINE SHUTDOWN:
7
TILT:
8
NOTE: Any of the selections above will light the tilt lamp when a tilted condition occurs and will sound the platform
alarm when the machine is also above elevation.
SOFT TOUCH:
9
3128411
Table 4-1. Machine Configuration Programming Information
Number
0
NO GLOW PLUGS: No glow plugs installed.
1
AIR INTAKE: Glow plugs installed in the air intake on the manifold.
2
IN-CYLINDER: Glow plugs installed in each cylinder.
0
DISABLED: Automatic pre-glow time determined by ambient air temperature;
engine start can be attempted at any time during pre-glow.
1
ENABLED: Automatic pre-glow time determined by ambient air temperature; engine
start is NOT permitted until pre-glow is finished.
0
DISABLED: No engine shutdown.
1
ENABLED: Shutdown engine when coolant temperature is greater than 110 deg. C
or the oil pressure is less than 8 PSI.
1
5 DEGREES: Reduces the maximum speed of all boom functions to creep when
tilted more than 5 degrees and above elevation; also reduces drive speed to
creep.
2
4 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted
more than 4 degrees and above elevation; also reduces drive speed to creep.
3
3 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted
more than 3 degrees and above elevation; also reduces drive speed to creep.
4
4 DEGREES + CUT: Reduces the maximum speed of all boom functions to creep
when tilted more than 4 degrees and above elevation; also disallows tower lift up,
tower telescope out, drive, main telescope out and main lift up.
5
3 DEGREES + CUT: Reduces the maximum speed of all boom functions to creep
when tilted more than 3 degrees and above elevation; also disallows tower lift up,
tower telescope out, drive, main telescope out and main lift up.
0
NO: No soft touch system installed.
1
YES: Soft touch system installed.
Description
1250AJP
SECTION 4 - JLG ANALYZER
Default
Number
2
0
1
1
0