Twr Angl1 Invalid Angle; Twr Angl2 Invalid Angle - JLG 1250AJP Troubleshooting Manual

Hide thumbs Also See for 1250AJP:
Table of Contents

Advertisement

1.358 TWR ANGL1 INVALID ANGLE

Flash Code: 8-4
Tower angle 1 (right side) invalid angle. Tower boom angle sensor #1 (Right) is reporting an invalid angle, over +85° or less
than -30°.
Note Pretest Instructions
1.358.1 Read fault log
1.358.2 Access tower boom angle
sensor 1 (Right) [X099] and
2 (Left) [X100]
1.358.3 Access tower boom angle
sensor #1 (Right) [X099]
1.358.4 Fully retract and lower
boom. ANALYZER ⇒ DIAG-
NOSTICS ⇒ BOOM SEN-
SORS ⇒ TOWER ANGLE 1
(and 2) SENSOR
1.358.5 Calibrate boom sensors.
See 5.8 Boom Sensor Cali-
bration on Pg. 309.

1.359 TWR ANGL2 INVALID ANGLE

Flash Code: 8-4
Tower angle 2 (left) invalid angle. Tower boom angle sensor #2 (Left) is reporting an invalid angle, over +85° or less than -
30°.
Note Pretest Instructions
1.359.1 Read fault log
1.359.2 Access tower boom angle
sensor 1 (Right) [X099] and
2 (Left) [X100]
1.359.3 Access tower boom angle
sensor #2 (Left) [X100]
3128411
SECTION 1 - FAULT DICTIONARY AND SELECTED TROUBLESHOOTING
Test
Are any of the following faults active on the
machine? BOOM ANGLE SENSOR #1 (or 2)
COMMUNICATIONS FAULT
Is there any lose mounting hardware, etc.?
Check the sensors aren't swapped by unplug-
ging tower boom angle sensor #1 (Right)
[X099]. Does the BOOM ANGLE SENSOR #1
COMMUNICATIONS FAULT show?
Are both sensor angles approximately -4.3° ±
1.5°?
Did boom calibrate successfully?
Test
Are any of the following faults active on the
machine? BOOM ANGLE SENSOR #2 (or 1)
COMMUNICATIONS FAULT
Is there any lose mounting hardware, etc.?
Check the sensors aren't swapped by unplug-
ging tower boom angle sensor #2 (Left)
[X100]. Does the BOOM ANGLE SENSOR #2
COMMUNICATIONS FAULT show?
1250AJP
Result
Corrective Action
Yes
Troubleshoot them first
No
Go to step 1.358.2
Yes
Repair as needed
No
Keep access to tower boom angle sensor #1
(Right) [X099] open.
Go to step 1.358.3
Yes
Go to step 1.358.4
No
Ensure harnesses go to correct sensor, tower
boom angle sensor #1 (Right) [X099] with Red,
Blue, and Black wires; and #2 (Left) [X100] with
Orange, Yellow and Black wires. See Figure 2-13.
BLAM Electrical Schematic on Pg. 201 for
details.
Yes
Go to step 1.358.5
No
Replace sensor out of specified range
Yes
Troubleshooting complete
No
Troubleshoot according to calibration fault
Result
Corrective Action
Yes
Troubleshoot them first
No
Go to step 1.359.2
Yes
Repair as needed
No
Keep access to tower boom angle sensor #2
(Left) [X100] open.
Go to step 1.359.3
Yes
Go to step 1.359.4
No
Ensure harnesses go to correct sensor, tower
boom angle sensor #1 (Right) [X099] with Red,
Blue, and Black wires; and #2 (Left) [X100] with
Orange, Yellow and Black wires. See Figure 2-13.
BLAM Electrical Schematic on Pg. 201 for
details.
1-161