Pool And/Or Hot Tub Heating - Central Boiler e-Classic 1450 IR Owner's Manual

Outdoor wood gasification furnace
Table of Contents

Advertisement

Pool and/or Hot Tub Heating

Valves should be installed so the heat exchanger can be
isolated and bypassed when shock-treating or adding
chemicals to a pool or hot tub (Fig. 34). Incorrect
chemical concentrations can cause rapid corrosion to
the heat exchanger. Bypassing the heat exchanger is
recommended until the pH has stabilized between 7.2
and 7.8.
If the swimming pool or hot tub is salt water treated, the
heat exchanger should be a shell and tube type (p/n 148,
151 or 177). See the Hydronic Component Selection
Guide (p/n 2482) for more detailed information.
CAUTION
Do not install a swimming pool heat exchanger
inside a home or building below the level of the
pool as a damaged heat exchanger may result in
extensive flooding and draining of the pool.
Fig. 34
Section 1 - Outdoor Furnace Installation
Do not use automotive or ethylene glycol
antifreeze in an outdoor furnace connected to
a swimming pool heat exchanger as a damaged
heat exchanger may cause severe personal
injury, death, or substantial property damage.
Do not operate the outdoor furnace frequently
or for extended periods of time with the water
temperature below 150˚F (65˚C) as this will result
in more condensation in the firebox that can lead
to corrosion.
pool gpm flow, a bypass balancing valve must be used to
bypass a portion of the pool water. There should be a shut-off
valve installed on the supply and return line to and from the
NOTE
pool. Close these valves and fully open the bypass balancing
Outdoor furnace water temp
valve when chemically treating ("shocking") the pool or hot tub
setpoint should be set at
185˚F (85˚C) minimum.
to stop the flow of the low pH water to the heat exchanger.
These valves can be opened only after the pH has reached
the safe level as recommended by the pool or hot tub
manufacturer. Return the bypass balancing valve to the
previously adjusted position.
WARNING
CAUTION
Pools and hot tubs typically have high
water flow rates, from 30-50 gpm (114-189
lpm) for residential and higher for commercial
applications. Because the MP Series is a high
efficiency heat exchanger and does not require the full
29