The E-Classic 1450 outdoor hydronic heater by Central Boiler is listed by OMNI-Test Laboratories to the applicable
portions of the following standards: UL 2523-2009 Solid Fuel-Fired Hydronic Heating Appliances, Water Heaters and
Boilers, CAN/CSA-B366.1-M91 (R2007) Solid-Fuel-Fired Central Heating Appliance. Dual Fuel models tested to
applicable portions of ANSI Z21.20a-2008 Automatic Gas Ignition Systems and Components and certified to add to an
existing heating system.
The E-Classic includes two 4-foot stainless steel insulated chimney sections (6" in diameter, p/n 6500004). Use only
stainless steel solid fuel chimneys specified by Central Boiler. Maximum draft is marked on nameplate.
French Owner's Manual and decal set available upon request from your dealer.
(Manuel d'installation en français et décalcomanies disponible sur demande auprès de votre revendeur)
Manuel d'installation en français : p/n 9000202
Thermal Output Rating*: Manufacturer's Rated Heat Output Capacity: 200,000 Btu/hr
Annual Efficiency Rating*: 84% (lower heating value), 77% (higher heating value)
*Performance is a product of the combustion rate, combustion efficiency and heat exchange efficiency with a single fuel load without refueling.
Results vary based on wood species, wood quality, wood quantity and moisture content. Efficiencies are determined under the same test conditions
using higher heating value, lower heating value and annual fuel utilization efficiency (AFUE).
This heater meets the 2015 U.S. Environmental Protection Agency's crib wood emission limits for wood heaters sold after May 15, 2015.
Under specific test conditions this heater has been shown to deliver heat at rates ranging from 0 to 214,271 Btu/hr.
This wood heater has a manufacturer-set minimum low burn rate that must not be altered. This wood heater needs periodic inspection and
repair for proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in
this manual.
DO NOT OVERFIRE THIS HEATER. Attempts to achieve heat output rates that exceed heater design specifications can result in permanent
damage to the heater.
Any person(s) operating a hydronic heater must comply with all applicable laws, including but not limited to local ordinances.
Improper use or failure to maintain the hydronic heater may cause nuisance conditions. The person(s) operating a hydronic heater is/are
responsible for operation in a manner that does not create a nuisance condition. Meeting the setback distance and stack height recommendations
from the manufacturer and requirements in applicable State and local regulations may not always be adequate to prevent nuisance conditions
in some areas due to terrain or other factors.
Operating an outdoor furnace may not be suitable to some individuals' abilities or lifestyles. Be sure to review the Owner's Manual for the
appliance with your dealer.
- Register at time of purchase for FREE 25 Year Limited Warranty -
For parts and accessories, service or repairs, call your authorized Central Boiler dealer or heating contractor. Record
the information below for future reference.
Model
Dealership Name
Owner Name
Central Boiler, Inc.
20502 160th Street • Greenbush, MN 56726
www.CentralBoiler.com
Videos to supplement the Owner's Manual are available at
www.youtube.com/centralboilerinc
Watch tips on initial startup, testing system water and more.
Verify your warranty at
Serial Number
Décalcomanies : p/n 7000041
CentralBoiler.com/w25
Installation Date
Phone Number

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents