[RS-232C control flowchart]
Command is sent successfully.
Command is executed successfully.
Checking execution of
command (sending out
check command)
OK
END
[Method of checking state of projector]
To normal operation
Enter password.
Send out "00PASS****."
No NAK returned
Check the following.
• The ID code is out of the valid range.
• Check that the function code is
correct.
• Check that the data code is correct.
• Check that the projector is able to
NG
issue the return command.
→ Check the projector's operation
using the 00vST command.
Note: In the following cases, NAK is
Sending "00vST"
0–3
Checking response to "00vST"
6
START
Sending out command
Awaiting response
from projector
NAK returned
Command is sent successfully.
Command execution fails.
returned even when the
projector is in normal condition.
• Immediately after the power is
turned on (about 20 seconds to 2
minutes)
• During input switching
• During auto positioning
• During password lock
4
5
Projector is functioning.
Use "00FNCOFF" to cancel the current function.
5
No response for
1 second or longer
Command sending fails.
Check the following.
• Check that the command begins
with "00".
• The projector is not supplied with
AC power.
→ Check that AC power cord is
connected.
→ Turn on the power. (Turn on the
circuit breaker or main switch.)
• Not connected with the projector.
→ Check that the RS-232C cable is
connected.
→ Check the RS-232C cable for
electrical discontinuity.
• There is no projector with the
specified ID in the daisy chain
configuration.
→ Check that the ID is correct.
→ Check whether that there is a
projector of which power (AC) is
turned off in the daisy chain
configuration.
Projector error
Send out "00vER" to check error details.
Recover from error state.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xd8100luXd8100u(bl)

Table of Contents