Venting Requirements; Installation Instructions; Prepare Location - KitchenAid KVWB400DSS0 Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4cm) wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION INSTRUCTIONS
I.
2.
3.
Prepare
Locat
on
It is recommended
that the vent system be installed before
hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
Check your ceiling height and the hood height maximum
before you select your hood.
Disconnect
power.
Determine which venting method to use: roof, wall, or non-
vented.
9. Drill 3/le"(4.8 mm) pilot holes at all locations where screws are
being installed into wood.
10. Install 2 - 5 x 45 mm mounting screws. Leave a 1/4"(6.4 mm)
gap between the wall and the back of the screw head to slide
range hood into place.
(6.4 turn)
_
Select a flat surface for assembling the range hood. Place
covering over that surface.
Vent Cover Support Bracket Installation
r
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
Installations using telescoping
upper and lower vent cover
assembly
1. Position vent cover bracket on wall about 1/8"(3.0 mm) away
from the ceiling.
2. Mark the hole locations.
3. Drill %" (9.5 mm) holes for wall anchors and insert anchors
flush with the wall.
4. Using 2 or more people, lift range hood onto covered surface.
Range Hood Mounting Screws Installation
5. Determine and mark the centerline on the wall where the
canopy hood will be installed.
6. Select a mounting height between a minimum of 24"
(61.0 cm) for an electric cooking surface, a minimum of 27"
(68.6 cm) for a gas cooking surface, and a suggested
maximum of 36" (91.4 cm) above the range to the bottom
of the hood. Mark a reference line on the wall.
7. Tape template in place, aligning the template centerline and
bottom of template with hood bottom line and with the
centerline marked on the wall.
I
I......................................
A
=
8.
i
l'i
_
i
_i i¸¸
B
J
_EA_ _hh
,i_¸ _IOUNTI_G TEmPLaTE
'_',I_ %7% t1_
4/
C
A. Centerline
B. Fastener locations
C. Mounting height reference
Mark centers of the fastener locations through the template
to the wall.
IMPORTANT: All canopy mounting screws must be installed
into wood. If there is no wood to screw into, additional wall
framing supports may be required.
Remove the template.
A. 8 x 40 mm drywall anchors
B. Centerline on waft
C. Vent cover support bracket
D. 5 x 45 mm screws
4. Attach vent cover support bracket to wall.
Complete Preparation
1. Determine and make all necessary cuts in the wall for the vent
system. Install the vent system before installing the hood. See
"Venting Requirements"
section.
2. Determine the required height for the home power supply
cable and drill a 1W' (3.2 cm) hole at this location.
3. Run the home power supply cable according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough 1/2"conduit and wires from
the fused disconnect
(or circuit breaker) box to make the
connection
in the hood's electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
4. Use caulk to seal all openings.
Install In-Line Smart Kit - Optional
NOTE: Your range hood can work with either an internal or an in-
line (external) blower motor system. An optional In-Line Smart Kit
(purchased separately) allows the blower motor that comes with
this range hood to be installed in a location other than inside the
range hood cavity.
CAUTION: To reduce the risk of fire and electric shock, install this
range hood only with the In-Line Smart Kit manufactured
by
Whirlpool, Part Number W10692945.
For installation see the In-Line Smart Kit installation instructions.
See the "Assistance
or Service" section to order.
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kvwb406dss0

Table of Contents