Kyocera FS-3040MFP Service Manual page 61

Hide thumbs Also See for FS-3040MFP:
Table of Contents

Advertisement

Item No.
U411
Adjusting the scanner automatically
Description
Uses a specified original and automatically adjusts the following items in the scanner and the DP
scanning sections.
Scanner section: Original size magnification, leading edge timing, center line, input gamma, input
gamma in monochrome mode and matrix
DP scanning section: Original size magnification, leading edge timing, center line
Purpose
To perform automatic adjustment of various items in the scanner and the DP scanning sections.
Method
1. Press the start key.
2. Select the item. The screen for executing is displayed.
Display
ALL
ADJUST TABLE
ADJUST DP
Method: TABLE
1. Enter the target values which are shown on the specified original (P/N: 302FZ56990) execut-
ing maintenance item U425.
2. Set a specified original (P/N: 302FZ56990) on the platen.
3. Enter maintenance item U411.
4. Select [ADJUST TABLE] using the cursor up/down keys.
5. Press the start key. Auto adjustment starts.
6. When automatic adjustment has normally completed, [OK] is displayed. If a problem occurs
during auto adjustment, [NG XX] (XX is replaced by an error code) is displayed and operation
stops. Should this happen, determine the details of the problem and repeat the procedure
from the beginning.
7. To return to the screen for selecting an item, press the stop key.
Method: DP
1. Select [ADJUST DP] using the cursor up/down keys.
2. Set a specified original (P/N: 303LJ57010) in the DP.
3. Press the start key. Auto adjustment starts.
4. When automatic adjustment has normally completed, [OK] is displayed. If a problem occurs
during auto adjustment, [NG XX] (XX is replaced by an error code) is displayed and operation
stops. Should this happen, determine the details of the problem and repeat the procedure
from the beginning.
5. To return to the screen for selecting an item, press the stop key.
Description
Description
Performs automatic adjustment in the DP
scanning section following automatic
adjustment in the scanner section
Automatic adjustment in the scanner sec-
tion
Automatic adjustment in the DP scanning
section:
1-3-33
2LW/2LX-2
Original to be used
for adjustment (P/N)
302FZ56990/
303LJ57010
302FZ56990
303LJ57010