Connector
Pin
YC1
1
MOT1A
Connected to
2
MOT2A
main PWB
3
MOT1B
4
MOT2B
5
+24V6
6
GND
YC2
1
PILED
Connected to
2
GND
DP open/
3
OPSWN
close sen-
4
PILED
sor, DP origi-
nal sensor
5
GND
and DP tim-
6
ORGSWN
ing sensor
7
PILED
8
GND
9
TIMSWN
YC3
1
DPMOT1A
Connected to
2
DPMOT2A
DP paper
3
DPMOT1B
feed motor
4
DPMOT2B
YC4
1
+24V6
Connected to
2
PRESOLN
DP pressure
3
RELSOLN
solenoid
YC5
1
+24V6
Connected to
2
REVSOL
DP switch-
back sole-
noid
YC6
1
+24V6
Connected to
2
FEEDCL
DP paper
feed clutch
Signal
I/O
I
0/24 V DC (pulse)
I
0/24 V DC (pulse)
I
0/24 V DC (pulse)
I
0/24 V DC (pulse)
I
24 V DC
-
-
O
3.3 V DC
-
-
I
0/3.3 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
O
0/24 V DC (pulse)
O
0/24 V DC (pulse)
O
0/24 V DC (pulse)
O
0/24 V DC (pulse)
O
24 V DC
O
0/24 V DC
O
0/24 V DC
O
24 V DC
O
0/24 V DC
O
24 V DC
O
0/24 V DC
Voltage
DPPFM drive control signal
DPPFM drive control signal
DPPFM drive control signal
DPPFM drive control signal
24 V DC power from MPWB
Ground
3.3 V DC power to DPOCS
Ground
DPOCS: On/Off
3.3 V DC power to DPOS
Ground
DPOS: On/Off
3.3 V DC power to DPTS
Ground
DPTS: On/Off
DPPFM drive control signal
DPPFM drive control signal
DPPFM drive control signal
DPPFM drive control signal
24 V DC power to DPPRSOL
DPPRSOL: ON (Press)/Off
DPPRSOL: On (Release)/Off
24 V DC power to DPSBSOL
DPSBSOL: On/Off
24 V DC power to DPPFCL
DPPFCL: On/Off
2-3-22