Specification - Sharp AE-X2M14LR Service Manual

Muliti split type room air conditioners (outdoor unit)
Table of Contents

Advertisement

AEX2M14LR
CHAPTER 1.
AEX2M14LR
SPECIFICATIONS

[1] SPECIFICATION

ITEMS
Cooling capacity
2-INDOOR OPERATION
Heating capacity
2-INDOOR OPERATION
Moisture removal
✩ Electrical data
Phase
Rated frequency
Rated voltage
Rated current
Rated input
Power factor
Compressor
Refrigerant system
Noise level (at cooling)
Fan system
Drive
Air flow quantity (at cooling)
Fan
Connections
Refrigerant coupling
Refrigerant tube size Gas, Liquid
Maximum length (per unit)
Maximum length (total)
Maximum charge-less length
Maximum height difference
Additional Charge (per m)
Drain joint
Others
Safety device
Air filters
Net dimensions
Net weight
NOTE: The condition of star "✩"marked item are 'ISO5151':
*: Representative connection
INDOOR UNIT
AY-XPM7FR/9FR/12FR
kW
7K & 7K
3.8(1.8 – 4.3)*
kW
7K & 7K
4.4 (1.9 – 5.4)*
Liters/h
1.6
Single
Hz
50
V
230V
Cool
A
4.1 (1.6 – 5.3)*
Heat
A
4.4 (1.7 – 5.9)*
Cool
W
900(350– 1160)*
Heat
W
950 (370 – 1300)*
Cool
%
95
Heat
%
94
Type
Hermetically sealed DC twin rotary
Model
DA130A1F-28F
Oil charge
Ester oil VG74
Evaporator
Silt Fin and Grooved tube type
Condenser
Corrugate Fin and Grooved tube type
Control
Expansion valve
Name of refrigerant
R410A
Refrigerant volume
1680g
High/Med/Low
7FR: 37/34/28
dB(A)
9FR: 39/36/28
12FR: 40/37/29
High/Med/Low
.
7FR: 8.0/7.4/5.4
3
m
/min.
9FR: 8.6/7.9/5.6
12FR: 10.2/8.6/6.1
Cross flow fan
Flare type
3/8", 1/4"
m
25
m
40
m
25
m
10
g
15
mm
Connected part O.D.16
Compressor: Thermistor
Fan motors: Thermal fuse (indoor unit).
Thermal protector (Out door unit)
Fuse, Micro computer control
Anti-mold polypropylene net of injection type (Washable)
Width
mm
Height
mm
Depth
mm
kg
Service Manual
OUTDOOR UNIT
AE-X2M14LR
45
Direct drive
33
Propeller fan
790
950 (890+60)
278
645
198
323 (290+33)
10
51
1 – 1