Data Cables
The luminaire is equipped with two, 5-pin XLR connectors for DATA IN and DATA THRU (out)
applications. DATA IN requires a 5-pin, female XLR connector and DATA THRU requires a 5-pin,
male XLR connector. When purchasing or constructing data cables, it is important that not only the
correct cable type be used, but also quality cable to ensure a reliable DMX512 system. Your cabling
should meet the following USITT DMX specification requirements:
•
Suitable for use with EIA485 (RS485) operation at 250k baud.
•
Characteristic impedance 85-150 ohms, nominally 120 ohms.
•
Low capacitance.
•
Two twisted pairs.
•
Foil and braid shielded.
•
24 AWG min. gauge for runs up to 1000 feet (300m).
•
22 AWG min. gauge for runs up to 1640 feet (500m).
Note: Microphone type cables and other general purpose, two-core audio or signal cables are not
suitable for use with DMX512.
Refer to the USITT Recommended Practice for DMX512 guide for additional information regarding
DMX512 systems. How to obtain a copy is detailed in
The XLR 5-pin connectors should be wired as follows:
Data Thru
Cable Pinout
1
2
Male Conn.
02.97 04.000 1 0
I
NSTALLATION
Pin/Wire Code to XLR Connectors
Pin 1
Pin 2
Foil &
Braided
conductor
Shield
5
twisted
4
3
Data (-)
: P
D
OWER AND
ATA
"Additional Documentation" on page
Pin 3
Pin 4
1st
2nd
conductor
conductor
of 1st
of 1st
of 2nd
twisted
twisted
pair
pair
pair
Data (+)
Data (-)
24 J un e 20 14
C
R
ABLING
EQUIREMENTS
Pin 5
Data In
Cable Pinout
1st
2nd
conductor
of 2nd
5
twisted
pair
4
Data (+)
Female Conn.
2
2.
1
2
3
15