Download Print this page

Advertisement

Quick Links

Clearflood Large
BVP651
BGP221/231
At 90º 0,41m
Inrush Current (230VAC) (Apk/ms)
Luminaire Surge Protection
Luminaire Surge Protection with SPD Optional
LED800-4S
LED750-4S
LED700-4S
LED650-4S
LED600-4S
740 / 757
LED550-4S
LED500-4S
LED450-4S
LED400-4S
LED350-4S
LED650-4S
LED600-4S
LED570-4S
LED530-4S
830
LED490-4S
LED440-4S
LED400-4S
LED360-4S
LED310-4S
** Only in luminaires with CityTouch
T ambient = 25
Flux Reduction (%)
583 4430 000 20878 _C
© 06 / 2019, SignifyHolding. All rights reserved
At 0º 0,05m
At 15º 0,13m
2
2
2
80000
75000
70000
65000
60000
184
55000
50000
45000
40000
35000
65000
60000
57000
53000
184
49000
44000
40000
36000
31000
*only with OFA52 and S optics. (ETO based)
Type of electrical protection installation
MCB16A
MCB10A
Outdoor
C
30
C
35
C
º
º
º
-1%
-2%
If Ta<45
C, there are no restrictions in the position of the luminaire.
º
RG1
340/220
4KV
10KV
540
495
455
420
380
345
310
275
245
210
540
495
465
425
385
345
310
275
235
Maximum number of luminaires to install
B TYPE
C TYPE
B TYPE
C TYPE
40
C
45
C
º
º
-3%
-4%
1/20
Outdoor
Indoor
25
15
35
25
45*
35
45
25
15
35
25
45
35
1
3
1**
2**
Indoor
T ambient = 25
C
30
C
º
º
Flux Reduction (%)
-1%
Printed in Spain
Data subject to change without notice
0,25m
-40
24kg
-40
24kg
35
C
º
-2%

Advertisement

loading

Summary of Contents for Philips Clearflood Large BVP651

  • Page 1 Clearflood Large BVP651 BGP221/231 0,25m At 90º 0,41m At 0º 0,05m At 15º 0,13m Inrush Current (230VAC) (Apk/ms) 340/220 Luminaire Surge Protection Luminaire Surge Protection with SPD Optional 10KV Outdoor Indoor LED800-4S 80000 LED750-4S 75000 LED700-4S 70000 LED650-4S 65000 LED600-4S 60000 740 / 757 24kg...
  • Page 2 WARNING This luminaire must be installed by qualified personnel only Disconnect before servicing Use gloves to install/service the luminaire The space between U-shape bracket and luminaire could be a pinch point Keep hands clear during operation. Free rotation of the U-shape bracket can cause damage to painted parts Always follow this mounting instructions to fix the luminaire Never modify the luminaire nor the fixation locations for installation...
  • Page 3: Standard Version

    STANDARD VERSION Position A CITYTOUCH VERSION Position B 3/20...
  • Page 4 SET TILT    Unscrew Bolts 1 and 2 (2x) Set tilt of luminaire Fix screws 1 and 2 (2x) Do not forget to screw the For Australia, the maximum bolt with the torque indicated allowed tilt angle is 25º LUMINAIRE FIXATION (official installation fixation locations) Two screws...
  • Page 5: Mains Connector

    CITYTOUCH BOX INSTALLATION / FIXATION STANDARD, CONTROL LINE, DALI, DALI IN/OUT CONNECTIONS SECONDARY CONNECTOR (2x) MAINS CONNECTOR (Only DALI IN/OUT versions) Ø10-14 mm 2-4 mm Ø7-12 mm 0,5-1,5 mm 5/20...
  • Page 6 WIRE CONNECTION TO WIELAND The connectors are not for current interruption. Never connect or disconnect under load 6/20...
  • Page 7 TYPES OF MAINS CONNECTOR PSU, PSA (D13), PSDD (D18) CONNECTION Mains connector Class-I Mains connector Class-II LINE LINE (Brown) (Brown) GROUND (Yellow & Green) NEUTRAL NEUTRAL (Blue) (Blue) PSR (D4) CONNECTION Mains connector Class-I Mains connector Class-II LINE LINE (Brown) (Brown) GROUND (Yellow &...
  • Page 8 PSD, (D9) CONNECTION Mains connector Class-I Mains connector Class-II LINE LINE (Brown) (Brown) GROUND (Yellow & Green) NEUTRAL NEUTRAL (Blue) (Blue) DALI DALI DALI DALI DALI IN/OUT CONNECTION Mains connector Class-I Mains connector Class-II LINE LINE (Brown) (Brown) GROUND (Yellow & Green) NEUTRAL NEUTRAL...
  • Page 9 CITYTOUCH CONNECTION Ø10-14 mm 2-4 mm OPEN MAINS CONNECTOR CLOSE MAINS CONNECTOR WIRE CONNECTION TO WIELAND The connectors are not for current interruption. Never connect or disconnect under load CITYTOUCH CONNECTION Mains connector Class-I Mains connector Class-II LINE LINE (Brown) (Brown) GROUND (Yellow &...
  • Page 10 10 KV PROTECTION 10A max. 10/20...
  • Page 11 11/20...
  • Page 12 12/20...
  • Page 13 Have you already downloaded the Philips Service tag app? It helps you make LED maintenance easier and faster! 1.Download the app App herunterladen Descargar la app Télécharger l’application Android 2.Place tag on the fuse box 3.Register the product Stelle den Tag auf den Sicherungskasten...
  • Page 14 Annex I: Simplified EU Declaration of Conformity Hereby, Signify Holding declares that the radio equipment type included into the luminary is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.philips.com/lighting 01/2019 Signify I.B.R.S.
  • Page 15 15/20...
  • Page 16 16/20...
  • Page 17 17/20...
  • Page 18 18/20...
  • Page 19 19/20...
  • Page 20 The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V..