Settings; Setting For The Driving Depth; Switching The Staple Spacing In The Direction Of Movement; Conversion To Other Spacing Combinations - Senco SNS50 Instruction Manual

Wegmatik
Table of Contents

Advertisement

3.5

SETTiNGS

3.5.1 Setting the driving depth
Tools required:
If the operational pressure of the stapler cannot be set or
if the setting range is not sufficient, the driving depth can
be varied by adjusting the height-adjustable castors.
The axes of the height-adjustable castors are arranged
eccentrically on the roller bearers. By turning the roller
bearers the driving depth can be set.
Roller bearer
Illustration 3.5.1/1: Height-adjustable castors
Carry out the following steps:
1. Loosen the screws M5 x 25 on both guide roller brack-
ets (see illustration 3.4.2/1) approx. 2 revolutions.
2. Pull the roller bearers out of the guide roller brackets.
3. Push the roller bearers back in such a way that the
castors have the desired height.
4. Tighten the screws M5 x 25.
iNfO
If the castors are in the deepest position and the driving
depth is still too low, this is due to insufficient compressed
air supply. The solution:
● Use a more powerful compressor.
● Shorten the compressed air supply
● Use a supply line with a larger cross-section.
8
● 1 Allen key 4 mm
(included in delivery)
Height-adjustable
castor
3.5.2 Switching the staple spacing in the direction
of movement
The staple spacing can be switched using the lever
shown in illustration 3.5.2/1 from 70 mm (narrow) to 140
mm (wide).
Illustration 3.5.2/1: Switching the staple spacing
To switch the staple spacing, carry out the following steps:
1. Tip the switch lever against the spring pressure to the
right.
2. Swing the switch lever into the desired position.
3. Let the switch lever snap into position using spring
pressure.

3.5.3 Conversion to other spacing combinations

Tools required:
By default, the staple spacing can be set to 70 mm and
140 mm. By exchanging the switch cam (see „accesso-
ries") other spacing pairs can be implemented (45/90 mm
or 60/90 mm).
Switch cam
Illustration 3.5.3/1: Exchanging the switch cam (view from
below)
The switch cam is attached to the counter wheel with 2
screws.
To exchange the switch cam, carry out the following steps:
1. Loosen the fastening screw shown in illustration
3.5.3/1.
2. Turn the counter wheel by 180°.
3. Loosen the second fastening screw, which is now
accessible.
4. Take the switch cam off the counter wheel.
5. To install the exchanged cam, reverse the procedure.
wide
narrow
1 Allen key 4 mm
(included in delivery)
Counter wheel
Fastening screw