Valve Access - Outdoor Lifestyles Dakota 42-B Owner's Manual

Hide thumbs Also See for Dakota 42-B:
Table of Contents

Advertisement

E. Valve Access After Installation
• The gas valve can be accessed after installation from
behind the cement refractory panel on the right side of
the fireplace.
• Lift doors out and set aside. There is a washer under each
door. Be careful not to lose those washers.
Washer
Figure 6.1
Lift Out Doors
• Remove logs if access is necessary after installation is
complete. See Section 9.C. Remove logs in reverse order
of set up.
• Remove grate if access is necessary after installation is
complete. (Refer to Section 9.B.)
• Remove two screws on side of pilot shield and remove
shield.
Figure 6.2
Remove Pilot Shield
• Use a phillips screwdriver to remove the two screws
securing the refractory retaining strip. Remove the
refractory side panel and set aside.
Figure 6.3
Loosen Refractory Retaining Strip
Outdoor Lifestyles by Hearth & Home Technologies • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev R • 07/01/15
• Remove the inside valve access panel by lifting it up and
out.
Figure 6.4
Remove Valve Access Panel
• Use a phillips screwdriver to remove the exterior valve
access panel (remove four screws).
Figure 6.5
Remove Exterior Valve Access Panel
• Use a manometer on the lower out pressure tap. Start
up the fireplace to verify the pressure and adjust as
necessary. Reverse these steps to reassemble before log
positioning.
Figure 6.6
Connect Manometer
13