STAGE 2 HP LOCK TEMP

Default is off (heat pump stage 2 operates
normally). Use this setting in dual fuel applications
to lock in the 2nd stage compressor when the
outdoor temperature is at or less than the LOCK
Configuration
Multi-stage Cooling for Heat Pump/Non-Heat Pump
Heating - Non-Heat Pump (1 or 2 stages)
Heating - Heat Pump with NO backup heat
Heating - Heat Pump w/electric heat (2-stage: 1compr/1backup)
Heating - Heat Pump w/electric heat (3 stage: 2compr/1backup)
Heating - Heat Pump w/electric heat (3 stage: 1compr/2backup)
Heating - Heat Pump w/electric heat (4 stage: 2compr/2backup)
Heating - dual fuel (2-stage: 1compr/1backup)
Heating - dual fuel (3 stage: 1compr/2backup)
Heating - dual fuel (3 stage: 2compr/1backup)
Heating - dual fuel (4 stage: 2compr/2backup)
TEMP set point. Scroll to STAGE 2 HP LOCK
TEMP; press ENTER. Use - + option to select a
LOCK TEMP between -40 and 75ºF. Press < to
return to previous menu.