Description of unit
3.5

Technical data

Voltage:
Max. current consumption:
Power cord:
Acceptance capacity:
Max. operating pressure:
Volume flow at 12 MPa
(120 bar) with water:
Max tip size:
Max. temperature of the
coating material:
Max viscosity:
Weight:
Special high-pressure hose:
Dimensions (L X W X H):
Vibration:
Max sound pressure level:
* Place of measuring: 1 m in distance from the unit and 1.6
m above the floor, 12 MPa (120 bar) operating pressure,
reverberant floor.
3.6

Transportation in vehicle

Secure the unit with a suitable fastening.
4.

Starting operation

4.1
High-pressure hose, spray gun and
separating oil
1. Screw the pressure gauge (1) to the coating material outlet
(Fig. 2, Item 2).
2. Screw the high-pressure hose (3) to the coating material
outlet on the pressure gauge (Fig. 2, Item 4).
3. Screw the spray gun (5) with the selected tip onto the high-
pressure hose.
4. Tighten the union nuts at the high-pressure hoses firmly so
that coating material does not leak.
1
4
2
3
100~110 Volt AC, 50/60 Hz
9.5 A @ 110VAC
3 x 1.5 mm
– 6 m
2
900 Watt
214 bar (21.4 MPa)
1.62 l/min
0.021 inch – 0.53 mm
43°C
20.000 MPa·s
15.2 kg
6,35 mm, 15 m-18 NPSM
480 x 360 x 405 mm
Spray gun does not
exceed 2.5m/s
2
80 dB (A) *
GB
5. Fill the oil cup with EasyGlide (Fig. 3). Do not use too much
EasyGlide, i.e. ensure that no EasyGlide drips into the coating
material container.
EasyGlide prevents increased wear and tear to the
packings.
Attention
4.2

Connection to the mains network

The unit must be connected to an appropriately-
grounded safety outlet.
Attention
Before connecting the unit to the mains supply, ensure that the line
voltage matches that specified on the unit's rating plate.
4.3
Cleaning preserving agent when starting-up
of operation initially
1. Immerse the suction tube (Fig. 4 Item 2) return hose (1) into a
container with a suitable cleaning agent.
2. Turn the pressure control knob counterclockwise (3) to
5
minimum pressure.
3. Open the relief valve (4), valve position PRIME
(k circulation).
4. Switch the unit (5) ON.
5. Wait until the cleaning agent exudes from the return hose.
6. Close the relief valve, valve position SPRAY (p spray).
7. Pull the trigger of the spray gun.
8. Spray the cleaning agent from the unit into an open collecting
container.
8
Starting operation
P20

Hide quick links: