1.7

NIGHT SET Mode

When the OFF timer is set, the NIGHT SET circuit automatically activates.
The NIGHT SET circuit maintains the airflow setting made by users.
The NIGHT SET circuit continues heating or cooling the room at the set temperature for the first
The NIGHT SET
one hour, then automatically raises the temperature setting slightly in the case of cooling, or
Circuit
lowers it slightly in the case of heating, for economical operations. This prevents excessive
heating in winter and excessive cooling in summer to ensure comfortable sleeping conditions,
and also conserves electricity.
Cooling Operation
Heating Operation
Function and Control
0.5°C
1 hour
+0.5°C
Timer operation
temperature shift
Night Set Circuit ON
Thermostat
setting
Timer operation
Night Set Circuit ON
Temperature
setting + 0.5°C
Temperature
settting
Operation stops
at the set hours
(R4421)
2°C
1 hour later
Main Functions