Control Specification; Mode Hierarchy - Daikin FTKS20DVMW(L) Service Manual

Hide thumbs Also See for FTKS20DVMW(L):
Table of Contents

Advertisement

SiENBE04-507A

3. Control Specification

3.1

Mode Hierarchy

There are two modes; the mode selected in user's place (normal air conditioning mode) and
Outline
forced operation mode for installation and providing service.
1. For heat pump model
Detail
2. For cooling only model
Unless specified otherwise, an indoor dry operation command must be regarded as cooling
Note:
operation.
Function and Control
There are following modes; stop, cooling (includes drying), heating (include defrosting)
Air conditioner control mode
Forced operating mode
Forced cooling (for Pump Down Operation)
Normal operating mode
Cooling
Heating
Defrosting
Stop mode (except for cooling/heating modes by indoor command)
Preheat operation
During C (capacitor) is discharging
Stop
There are following models; stop and cooling (including drying).
Air conditioner control mode
Forced operating mode
Forced cooling (for Pump Down Operation)
Normal operating mode
Cooling
Stop mode (except for cooling modes by indoor command)
Preheat operation
During C (capacitor) is discharging
Stop

Control Specification

(R2829)
(R2830)
61

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents