Suz-Ka09Na Suz-Ka12Na Suz-Ka15Na - Mitsubishi Electric SEZ-KD09NA4.TH Product Manual

M-series
Hide thumbs Also See for SEZ-KD09NA4.TH:
Table of Contents

Advertisement

3-1. SPECIFICATIONS

SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA

NOTES : *1.Rating conditions (cooling)-Indoor : D.B. 26.7°C(80°F), W.B. 19.4°C(67°F)
(heating)-Indoor : D.B. 21.1°C(70°F), W.B. 15.6°C(60°F)
*2.Rating conditions(heating)-Indoor : D.B. 21.1°C(70°F), W.B. 15.6°C(60°F)
Operating range
Due to continuing improvement, above specification may be subject to change without notice.
Maximum
Cooling
Minimum
SEZ-8
SEZ Ducted Heat Pump Systems (August 2014)
Maximum
Heating
Minimum
Indoor intake air temperature
D.B. 35°C(95°F), W.B. 21.7°C(71°F)
D.B. 19.4°C(67°F), W.B. 13.9°C(57°F)
D.B. 26.7°C(80°F), W.B. 19.4°C(67°F)
D.B. 21.1°C(70°F), W.B. 15.6°C(60°F)
Outdoor : D.B. 35°C(95°F), W.B. 23.9°C(75°F)
Outdoor : D.B. 8.3°C(47°F), W.B. 6.1°C(43°F)
Outdoor : D.B. -8.3°C(17°F), W.B. -9.4°C(15°F)
Outdoor intake air temperature
D.B. 46°C(115°F)
D.B. -10°C(14°F)
D.B. 24°C(75°F), W.B. 18°C(65°F)
© 2014 Mitsubishi Electric US, Inc.
D.B. -20°C(-4°F), W.B. -21°C(-5°F)