3-2. EXTERNAL DIMENSIONS

SEZ-KD09NA4

SEZ-KD12NA4

SEZ-KD15NA4

SEZ-KD18NA4

15(19/32)
Drain
2×2-ø2.9(1/8)
Refrigerant piping
1
flare connection (gas)
Note2
Required space for service and maintenance
Model
A
700
SEZ-KD09NA4
(27-9/16)
SEZ-KD12NA4
900
(35-7/16)
SEZ-KD15NA4
1100
SEZ-KD18NA4
(43-5/16)
Note1. Use M10 screw for the suspension bolt (field supply).
2. Keep the service space for the maintenance at the bottom.
3. This chart indicates for SEZ-KD15NA4 model, which has 3 fans.
SEZ-KD09,12NA4 models have 2 fans.
SEZ-KD18NA4 model has 4 fans.
4. When an inlet duct is used, remove the air filter (supply with the unit), then install the filter (field supply) at suction side.
Due to continuing improvement, above specification may be subject to change without notice.
SEZ-12
SEZ Ducted Heat Pump Systems (August 2014)
Drain pipe(O.D.ø32(1-1/4))
345(13-19/32)
(Emergency draining)
2×E-ø2.9(1/8)
Air
outlet
10(13/32)
49
625(Suspension bolt pitch)
(1-15/16)
(24-5/8)
pipe(O.D.ø32(1-1/4))
700(27-9/16)
23(29/32)
677(26-21/32)
Control box
10(13/32)
116
70
(4-19/32)
(2-25/32)
270(10-21/32)
Drain pipe(O.D.ø32(1-1/4))
Refrigerant piping
2
(Spontaneous draining)
flare connection (liquid)
175±5(6-29/32±7/32)
(Actual length)
Access door
B
C
D
E
F
752
798
660
600
7
(29-5/8)
(31-7/16)
(26)
(23-5/8)
952
998
860
800 1000 860
9
(37-1/2)
(39-5/16)
(33-7/8)
(31-1/2)
1152
1198
1060
1000
1200
11
(45-3/8)
(47-3/16)
(41-3/4)
(39-3/8)
Suspension bolt hole
4-14×30(9/16×1-3/16) Slot
L-ø2.9(1/8)
Air
inlet
Knockout hole ø27(1-3/32)
(Indoor/outdoor connecting line)
Knockout hole ø27(1-3/32)
(Remote controller transmission line)
Terminal block (Indoor/outdoor connecting line)
Terminal block (Remote controller transmission line)
Less than 300
(11-13/16)
Drain hose (I.D.ø32(1-1/4))
<accessory>
G
H
J
K
L
800
660
500
5
16
(31-1/2)
(26)
(19-11/16)
(33-1/16)
700
1039
7
20
(39-3/8)
(33-7/8)
(27-9/16)
(40-29/32)
1060
900
1239
9
24
(47-1/4)
(41-3/4)
(35-7/16)
(48-25/32)
Unit: mm (inch)
37(1-15/32)
100(3-15/16)
20(13/16)
157.5(6-7/32)
12(1/2)
37(1-15/32)
Air filter
Ceiling surface
Access door
Make the access door at the appointed position properly
for service maintenance.
M
N
Gas pipe
Liquid pipe
1
2
839
790
(31-1/8)
ø9.52(3/8)
990
ø6.35(1/4)
(39)
ø12.7(1/2)
1190
(46-7/8)
© 2014 Mitsubishi Electric US, Inc.
mm(in.)