Replacing A Hot-Plug Fan - Fujitsu PRIMERGY RX200 S6 Operating Manual

Hide thumbs Also See for PRIMERGY RX200 S6:
Table of Contents

Advertisement

CSS components
8.1.3

Replacing a hot-plug fan

V
CAUTION!
Please observe the safety information in chapter
information" on page
In order to replace a defective fan, it is necessary to open the fan cover, because
the fans are not directly accessible.
The server is equipped with six fan units. Each fan unit consists of two separate
hot-plug fans.
A possible fan fault is reported by the CSS indicator lighting up on the front and
rear of the server (for more information about the behavior of these indicators,
see chapter
"Starting up and operation" on page 61
Service (CSS)" manual on the ServerView Suite DVD 2).
When the fan cover is open, the faulty fan can be identified by the corresponding
LED (see figure
24 on page
running.
100
29.
102) and can be replaced while the system is
Operating Manual
"Important
and the "Customer Self
RX200 S6