Ê If you want to remove a HDD module that is not defective, the drive must be
first set to "Offline" via the software (RAID controller configuration software).
Ê Unlock the HDD module as described in section
on page
97.
Ê Pull the HDD module out a few centimeters.
Ê Wait for at least 60 seconds.
I
This period is necessary for the RAID controller to recognize that a
HDD module has been removed and for the hard disk drive to come
to a stop.
Ê Pull the HDD module out completely.
Ê Install the new HDD module, as described in
page
97.
V
CAUTION!
If you have removed a HDD module and do not install a new one in
its place, put the dummy module back in its place for cooling, to
comply with EMC regulations (regulations regarding electromagnetic
compatibility), and for protection against fire. Ensure that the dummy
module engages correctly in the bay.