DSC Envoy NT9010 v1.0 Programming Worksheet page 5

Table of Contents

Advertisement

[006] Installer's Code
Default:
5555
[007] Master Code
Default:
1234
[008] Maintenance Code
NOTE:
Valid codes are 0000-9999. Enter AAAA to disable maintenance code.
Default:
AAAA
[012] Keypad Lockout Options
NOTE:
If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000
I _ ______I _ ______I _ ______I
000
I _ ______I _ ______I _ ______I
[013] First System Option Code
Default
Option ON
OFF
1
I _ _______I
OFF
2-3
I _ _______I
OFF
4
I _ _______I
OFF
5
I _ _______I
ON
6
I _ _______I
ON
7
I _ _______I
ON
8
I _ _______I
**The Temporal Three Fire Signal option must be used for Household Fire installations.
[014] Second System Option Code
Default
Option ON
OFF
1
I _ _______I
OFF
2
I _ _______I
OFF
3
I _ _______I
OFF
4
I _ _______I
OFF
5
I _ _______I
ON
6
I _ _______I
OFF
7
I _ _______I
OFF
8
I _ _______I
(2.2.2 "Access Codes" on page 20••)
I _ ______I _ ______I _ ______I _ ______I
(2.2.2 "Access Codes" on page 20••)
I _ ______I _ ______I _ ______I _ ______I
(2.2.2 "Access Codes" on page 20••)
I _ ______I _ ______I _ ______I _ ______I
(2.2.13 "Keypad Options" on page 34••)
Number of Invalid Codes Before Lockout (001-255 codes)
Lockout Duration (001-255 minutes)
Hardwired Zones are Normally Closed
For future use
Tampers/Faults Do Not Sound as Open
For future use
Audible Exit Fault Enabled
Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown
Temporal Three Fire Signal Enabled**
Arm / Disarm Bell Squawk enabled
Bell Squawk During Auto Arm
Bell Squawk On Exit Delay
Bell Squawk On Entry Delay
Bell Squawk On Trouble
Audible Exit with Urgency
Exit Delay Termination Enabled
Fire Bell is Continuous
••Refer to section xx and page xx in the Installation Guide.
S ec t i o n 2 : A d v a n c ed P ro g ra m m i n g
OFF
Hardwired Zones use End-of-Line Resistors 1.2.5 / 6
Tampers/Faults Sound as Open
Audible Exit Fault Disabled
Standard Pulsed Fire Signal
OFF
Arm / Disarm Bell Squawk disabled
No Bell Squawk During Auto Arm
No Bell Squawk On Exit Delay
No Bell Squawk On Entry Delay
No Bell Squawk On Trouble
Silent Exit Delay
Exit Delay Termination Disabled
Fire Bell Follows Bell Cut-off
Section/
Page #••
2.2.9 / 27
2.2.7 / 25
2.3.17 / 53
2.2.8 / 26
Section/
Page #••
2.2.5 / 24
2.2.7 / 25
2.2.7 / 25
2.2.7 / 25
2.2.9 / 27
2.2.7 / 25
2.2.7 / 25
2.2.8 / 26
3

Advertisement

Table of Contents
loading

Table of Contents