Stihl SR 200 Instruction Manual page 23

Hide thumbs Also See for SR 200:
Table of Contents

Advertisement

Available languages

Available languages

Metering Knob
1
2
Rotate the metering knob (1) for
N
infinitely variable discharge rate
Position 1 = minimum flow rate
Position 6 = maximum flow rate
The numbers on the metering knob must
be lined up with the lug (2) under the
knob.
Discharge Rate
The discharge rate (l/min) depends on
the metering knob setting and the spray
tube angle.
SR 200
Discharge rate (l/min) without pressure
pump
Spray tube angle
Knob setting
- 30°
1
0.24
0.17
2
0.82
0.66
3
1.42
1.13
4
2.2
1.66
5
2.69
2.13
6
2.91
2.25
Discharge rate (l/min) without pressure
pump, with ULV nozzle
Spray tube angle
Knob setting
- 30°
0.5
0.05
0.04
0.65
0.08
0.07
0.8
0.12
0.09
Discharge rate (l/min) with pressure
pump (special accessory)
Spray tube angle
Knob setting
- 30°
1.0
0.64
1.6
1.7
2.0
2.59
Discharge rate (l/min) with pressure
pump (special accessory) and ULV
nozzle
Spray tube angle
Knob setting
- 30°
0.5
0.15
0.65
0.2
0.8
0.37
Checking Flow Rate
Place the unit on the ground.
N
+ 30°
Fill the container with water up to
N
10 liter mark.
0.11
0.46
Machines without pressure pump
0.84
Set the "standard" metering knob to
N
1.1
6.
1.46
Start the machine.
N
1.52
Hold the spray tube horizontally, run
N
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
+ 30°
The time required to spray 5 liters fluid
0.03
should be between 110 and
150 seconds.
0.05
0.08
Machines with pressure pump (special
accessory)
Fit metering knob 2.0 in the nozzle.
N
Start the machine.
N
Hold the spray tube horizontally, run
N
+ 30°
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be between 100 and
130 seconds.
+ 30°
English
21

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents