Problems with the load size indicator or calibrating to zero

Problem
The display indicates
<25%
a load of
or no
load size is indicated
when the drum is
full.
The display indicates
a load greater than
<25%
, even though
the drum is empty.
The fault message:
Zero setting not
possible. Open the
door
appears in the
display.
Possible cause
There was laundry in
the drum when the
machine was
switched off. This has
decalibrated the
sensor from the zero
setting.
The load size sensor
has been
decalibrated from the
zero position.
The drum door is
closed.
Problem solving guide
Remedy
– Remove the laundry from the
drum.
– Switch off the washing
machine and leave the door
open.
– Switch on the washing
machine.
– Recalibrate the sensor to the
zero setting.
For instructions on how to do
this, see "Calibrating the load
sensor to zero".
Rotate the drum once. If it still
indicates a load greater than
<25%
, recalibrate the sensor to
the zero setting (see above).
– Open the drum door.
– Switch off the washing
machine and leave the door
open.
– Switch on the washing
machine.
– Try to recalibrate to zero
again.
53