JAYCO CAMPING TRAILERS
The following label should be kept permanently affixed to your RV.
Refer to your Warranty Packet for more information on the LP gas system
components.
I
P
NSTALLING
ROPANE
Ensure that all fasteners are secured before traveling.
Single Cylinder Mounted On A-Frame (if so equipped)
1.
Connect the 3/8" low pressure hose to the outlet of the two stage regulator.
2.
Attach the regulator with the "Z" bracket on the center of the front wall with the
vent pointing down.
3.
Attach the protective plastic cover to the regulator.
4.
The regulator has a 90° elbow that directs the inlet toward the trailer curbside.
5.
Place the cylinder on the bracket provided on the A-frame and position it so
the outlet of the cylinder valve is pointed directly outward to the curbside wall.
6.
If a vinyl cylinder cover is provided, slip it over the cylinder and leave the
zipper open (if so equipped).
7.
Attach the 1/4" inverted flare x 24" Type 1 pigtail hose to the regulator inlet
and the right hand swivel nut to the cylinder valve.
8.
If applicable, close the cylinder cover zipper (if so equipped) up to the hose.
9.
Secure the cylinder to the A-frame bracket using the bolts, nuts and washers
provided.
Fig. 7.4 "Do not fill to more than
80%" label
C
(
)
YLINDER
S
WARNING
Fig. 7.5 Single cylinder
SECTION 7 –PROPANE SYSTEM
7-5