Miele PG 8061 Installations Plan page 5

Professional dishwasher
Hide thumbs Also See for PG 8061:
Table of Contents

Advertisement

Electrical connection (208 V)
Voltage (default)
Rated load
Fuse rating
Minimum cross-section
Length of electrical cord (UL 921) with plug
Electrical connection
Voltage (convertible)
Rated load
Fuse rating
Minimum cross-section
Length of electrical cord (UL 921) with plug
Electrical connection
Electrical connection (240 V)
Voltage
(default)
Rated load
Fuse rating
Minimum cross-section
Length of electrical cord (UL 921) with plug
Electrical connection
Voltage (convertible)
Rated load
Fuse rating
Minimum cross-section
Length of electrical cord (UL 921) with plug
Electrical connection
Cold water connections*
Max. temperature
Max. water hardness
Min. flow pressure
Min. flow pressure with extended water intake
Max. pressure
Throughput
Connection thread - on site (flat sealing)
Length of connection hose (supplied)
Length of the steam condensor hose
* Two cold water connections required: use supplied Y-adapter if only one cold water connection is available.
Installation plan PG 8061
3 AC 208V 60 Hz
5.8 kW
3 × 20 A
4 × AWG 12
approx. 6' 2"
NEMA L15-20
2 AC 208V 60 Hz
5.8 kW
2 × 30 A
3 × AWG 10
approx. 6' 2"
NEMA L6-30
3 AC 240V 60 Hz
5.8 kW
3 × 20 A
4 × AWG 12
approx. 6' 2"
NEMA L15-20
2 AC 240V 60 Hz
5.8 kW
2 × 30 A
3 × AWG 10
approx. 6' 2"
NEMA L6-30
68 °F
70 gpg
29 psi
5.8 psi
145 psi
2 gal/min
3/4" Male Garden Hose
Thread
(USA: 11.5 NH)
approx. 5' 7"
approx. 5' 7"
3 AC 208V 60 Hz
5.8 kW
3 × 20 A
4 × 3.3 mm²
approx. 1.9 m
NEMA L15-20
2 AC 208V 60 Hz
5.8 kW
2 × 30 A
3 × 5.2 mm²
approx. 1.9 m
NEMA L6-30
3 AC 240V 60 Hz
5.8 kW
3 × 20 A
4 × 3.3 mm²
approx. 1.9 m
NEMA L15-20
2 AC 240V 60 Hz
5.8 kW
2 × 30 A
3 × 5.2 mm²
approx. 1.9 m
NEMA L6-30
20 °C
70 °d
200 kPa
40 kPa
1,000 kPa
7.5 l/min
3/4" Male Garden
Hose Thread
approx. 1.7 m
approx. 1.7 m
page 4 / 8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents