Excell YSP User Manual

Excell YSP User Manual

Waterproof price computing scale

Advertisement

Quick Links

User Manual

Waterproof Price
Computing Scale
YSP
©EXCELL PRECISION CO., LTD. 2013. All rights reserved worldwide.
The information contained herein is the property of EXCELL PRECISION CO., LTD. and is
supplied without liability for errors or omissions. No part may be reproduced or used
except as authorized by contract or other written permission. The copyright and the
foregoing restriction on reproduction and use extend to all media in which the information
may be embodied.

Advertisement

Table of Contents
loading

Summary of Contents for Excell YSP

  • Page 1: User Manual

    Computing Scale ©EXCELL PRECISION CO., LTD. 2013. All rights reserved worldwide. The information contained herein is the property of EXCELL PRECISION CO., LTD. and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorized by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.
  • Page 3: Table Of Contents

    EXCELL PRECISION CO., LTD. TABLE OF CONTENTS INSTRUCTION FOR USE ...................... 2 1-1 F ........................5 EATURE 1-2 S ........................ 5 PECIFICATION 1-3 E ......................6 RROR ESSAGES 1-4 S ......................6 CREEN ISPLAY 1-5 P ....................... 7 OWER UPPLY CHAPTER 2 KEYBOARD FUNCTION ...................
  • Page 4: Instruction For Use

    EXCELL PRECISION CO., LTD. Thank you for purchasing Price Computing Scale. In order to operate smoothly, to last the durability, and to reduce the chance of breakdown for this product, please read this Manual carefully. Instruction for Use In order to prevent the scale from dust and static electricity, please fix the dustproof cover on the scale with double-sided adhesive.
  • Page 5 EXCELL PRECISION CO., LTD. If you want, you can use the four screws to lock the platter so that it will be more firm. When you lock ,please follow the order “1→2→3→4” push Please push the clip to take off the dust cover to clean Preparation before Using 1.
  • Page 6 EXCELL PRECISION CO., LTD. Due to the storage battery adopt the advanced free-maintaining technique, customers need not to replenish electrolyte. The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery. 1. The battery should be charged for 8~10 hours.
  • Page 7: Feature

    EXCELL PRECISION CO., LTD. Chapter 1 Product Introduction 1-1 Feature Sealed waterproof silica gel strip blocks water from infiltrating into the scale. Surrounded by waterproof grade sheeting to ensure the water free. 1/3,000~1/6,000 display resolution available Aluminum frames coated with anti-corrosion treatment for longer lifespan Stainless steel made feet and platter for anti-rusted.
  • Page 8: Error Messages

    EXCELL PRECISION CO., LTD. 144mm 313mm 250.4mm 1-3 Error Messages ⇒ The weight value is over 9 division of maximum capacity. ⇒ Zero value above 10% full scale. ⇒ Zero value below 10% full scale. ⇒ The internal value is over 350,000.
  • Page 9: Power Supply

    EXCELL PRECISION CO., LTD. 2. Unit Price 6 digits in total display the unit price of objects on platter. The decimal point floats two digits. 3. Total Price 6 digits in total display the total price of the objects on platter or the accumulation.
  • Page 10: Chapter 2 Keyboard Function

    EXCELL PRECISION CO., LTD. Chapter 2 Keyboard Function 0 ~ 9 : Number key. Press the keys to input the numbers (0 ~ 9) and to set unit price. CE : Press the key to clear the old unit price and then input the new one if you would like to change the unit price (If the unit price has been input for 3 seconds, you can input the new one immediately).
  • Page 11: Chapter 3 Operation Instruction

    EXCELL PRECISION CO., LTD. Chapter 3 Operation Instruction 3-1 Internal Value Display Mode Press Z key, when the display show “ ” ,then, press CE key immediately. The display will show internal value. Press 0 to exit the internal value mode and return to the weighing mode.
  • Page 12: External Weight Factory Default Setting

    EXCELL PRECISION CO., LTD. Press 1 ~ 6 to select pricing units. The scale will be back to weighing & price mode. The display will show the symbol indication “◄” for the request pricing unit. 1 ⇒ kg 2 ⇒ 100g 3 ⇒...
  • Page 13: Chapter 4 Function Setting

    EXCELL PRECISION CO., LTD. Chapter 4 Function Setting Press MC key do not release, and turn power on to enter function setting mode.     WEIGHT  UNIT PRICE    $/kg → ←            ⇒reserved     NET ...
  • Page 14 EXCELL PRECISION CO., LTD. pressTkey     WEIGHT  UNIT PRICE    $/kg → ←                NET          M+          TOTAL PRICE $  pressTkey Unit price reserved     WEIGHT  UNIT PRICE ...
  • Page 15: F3 ⇒ Stabilization (One Of Judgement Conditions ) ⇒ Reading Times

    EXCELL PRECISION CO., LTD. 4-1 F3 ⇒ Stabilization (One of judgement conditions) ⇒ Reading Times     WEIGHT  UNIT PRICE    $/kg → ←                NET          M+  TOTAL PRICE $       ...
  • Page 16: F5 ⇒Clear Unit Price Immediately After

    EXCELL PRECISION CO., LTD. 4-3 F5 ⇒Clear Unit Price Immediately After     WEIGHT  UNIT PRICE    $/kg → ←                NET          M+          TOTAL PRICE $  Press number key 0 , 1 to select 0 or 1 0 ⇒...
  • Page 17: Appendix 1 7-Segment Display Characters

    EXCELL PRECISION CO., LTD. Appendix 1 7-Segment Display Characters Number Display Letter Display Letter Display ℃ 01007021 ZSME100000074...

Table of Contents