D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing or fi nishing material closer than
the minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc).
Mantels - Combustible or Painted Surfaces
5
4
3
2-1/2
10
5
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (6000CL)
= 35-1/2 IN. (8000CL)
Note: All measurements in inches.
Note: Measurement is taken from top of the
opening, NOT the top of the fi replace.
Figure 5.3 Minimum Vertical and Maximum Horizontal
Dimensions
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. AB • 3/15
22
TO CEILING
18
12
11
10
9
8
25
7
19
6
18
17
16
15
14
13
12
11
Mantel Legs or Wall Projections - Combustible or
Painted Surfaces
32
FIREPLACE OPENING
A
If
A
Millimeters
B
Millimeters
Figure 5.4 Clearances to Mantel Legs or Wall Projections
TOP VIEW
A
MANTEL LEG OR WALL PROJECTIONS
B
minimum is ____, then
maximum is_____.
2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16
Inches
62
87
113
1
2
3
Inches
25
51
76
(Acceptable on both sides of opening.)
INTERIOR WALL
B
138
164
189
4
5
102
127

Hide quick links: