Titan CAPSPRAY 55 Training Manual page 27

Hvlp spray systems
Table of Contents

Advertisement

CAPSPRAY 2 Quart Remote
Assembly
1. Insert the handle through the air
fitting bracket and thread into the
fluid fitting. Tighten for at least
three (3) revolutions.
2. Tighten locking nut.
3. Push air tube over air tube fitting.
Ensure that the check valve assembly
is oriented as shown (see inset).
4. Convert the gun to pressure feed.
a. Loosen the retaining nut using a
wrench and remove the one-quart
cup assembly.
b. Pull the air tube off the air tube
fitting on the spray gun.
c. Push a supplied air tube cap over
the air tube fitting.
5.Connect hoses:
a. Make sure turbine is turned OFF
and unplugged.
b. Attach remote pressure pot to the
turbine via the hose configuration
shown below.
c.Tighten the air hose connections
by hand.
b.Tighten the fluid hose
connections with an adjustable
wrench.
CAPSPRAY has designed the Remote Cup System to add higher
material capacity to the EXCLUSIVE power and performance
found in CAPSPRAY's 105-5 Stage and 115-6 Stage Turbine models.
With quick air and fluid connections you can transform your
turbinesystem into a higher capacity sprayer, no need to add the
cost and weight of a bulky compressor system. The Remote Cup
System operates by using the higher air flow and pressure found
only in CAPSPRAY's five and six-stage units.
•The Remote Cup System doubles the reservoir capacity of
standard HVLP guns.
•Reduces arm and hand fatigue by removing the weight of the
material reservoir from the gun.
•Easier to paint inside cabinets and other hard to reach areas.
•Allows you to spray upside down.
•Weighs less than competitive two quart systems.
Features:
NOTE: Whip hose shown comes with 5 or 6 stage models
NOTE: If previously assembled, disconnect the 5 ft air whip hose from
the 30 ft air hose, add the supplied female quick-disconnect to the end of
the 30 ft air hose. Connect the 2 quart pressure pot as shown.
26
Model No. 0524203
2-quart pressure cup assembly
6-foot fluid hose
Integrated cup holder
Can be used with 5 and 6
stage units

Hide quick links: