The electrical power to the oven branch circuit must be shut off while
line connections are being made.
Do not use an extension cord with this appliance.
Electrical ground is required on this appliance. The free end of the green
wire (the ground wire) must be connected to a suitable ground. This
wire must remain grounded to the oven.
If cold water pipe is interrupted by plastic, non metallic gaskets, union
connections or other insulating materials, DO NOT use for grounding.
DO NOT ground to a gas pipe.
DO NOT have a fuse in the NEUTRAL or GROUNDING circuit. A fuse in
the NEUTRAL or GROUNDING circuit could result in an electrical shock.
Check with a quali ed electrician if you are in doubt as to whether the
appliance is properly grounded.
Failure to do so could result in death or serious injury.
Use a 3-wire, UL listed, 40-amp power supply cord (pigtail); or if local codes do
not permit ground through the neutral, use a 4-wire power supply cord rated at
250 volts, 40 amps and investigated for use with ranges.
Electrical Connection
To properly install your range, you must determine the type of electrical connection
you will be using and follow the instructions provided for it here.
Range must be connected to the proper electrical voltage and frequency as
specified on the model/serial number rating plate. All models are dual rated, and
designed to be connected to either 208/240V AC, 60Hz, 3-wire or 4-wire, two-
phase power supply.
Circuit Required
208V, 60Hz
12AMP
The electrical supply should be a 3-wire or 4-wire, two-phase AC. Install a
suitable conduit box (not furnished). An appropriately sized, U-listed conduit
connector must be used to correctly attach the conduit to the junction box.
IMPORTANT: Local Codes may vary; installation electrical connections and
grounding must comply with all applicable local codes.
If local codes permit grounding through the electrical supply neutral, connect both
the white neutral wire and the green ground wire from the oven to the white neutral
electrical supply wire.
WARNING
Electrical Shock Hazard
240V, 60Hz
15AMP