Power supply cord strain relief
Remove the knockout for the 40-amp supply cord.
Assemble a UL listed strain relief in the opening.
Feed the power supply cord behind the black horizontal cross brace and through
the strain relief, allowing enough slack to easily attach the wiring to the terminal
block.
Tighten strain relief screw against the power supply cord.
DIRECT WIRE
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to do so can result in death, re or electrical shock.
Be sure your appliance is properly installed and grounded by a qualified
technician. Ask your dealer to recommend a qualified technician or an authorized
repair service.
This appliance is manufactured with a green GROUND wire connected to the oven
chassis. After making sure that the power has been turned off, connect the flexible
conduit fromthe oven to the junction box using a U.L. listed conduit connector. The
Grounded Neutral and Ungrounded Neutral Graphics on the following pages and the
instructions provided, present the most common way of connecting the ovens. Your
local codes and ordinances, of course, take precedence over these instructions.
Complete electrical connections according to local codes and ordinances
WARNING
Electrical Shock Hazard
11