ABNORMAL OPERATION
ANY OF THE FOLLOWING ARE CONSIDERED TO BE ABNORMAL OPERATION
AND MAY REQUIRE SERVICING:
•
Yellow tipping of the hob burner flame.
•
Sooting up of cooking utensils.
•
Burners not igniting properly.
•
Burners failing to remain lit.
•
Burners extinguished by oven door.
•
Gas valves, which are difficult to turn.
IN CASE THE APPLIANCE FAILS TO OPERATE CORRECTLY, CONTACT THE
AUTHORIZED SERVICE PROVIDER IN YOUR AREA
Burner and Injector Characteristic Table
Burner
Position
Auxiliary
Front R
Semi-Rapid
Rear L and R
Dual Burner
Center Inner
Center Outer
2
1
a
a
Opening in grate for wok ring (provided) is located over left front burner.
Injector
Gas
Diam. (mm) Type
1.1
NG
0.7
LP (Propane)
1.29
NG
0.8
LP (Propane)
0.99*5
NG
0.56*6
LP (Propane)
2
3
a
Pressure
Rate
[i.w.c.]
[BTU/h]
4"
4967
10"
4879
4"
7055
10"
6472
4"
17882
10"
15586
2
2
3
4
17