Humiditrol ® Enhanced Dehumidification Accessory (Eda) - Lennox L7742U Programming And Application Manual

Comfortsense 7000 series
Hide thumbs Also See for L7742U:
Table of Contents

Advertisement

Scroll to HUMIDITY SETTINGS; press ENTER. Press the box below
DEHUMIDIFY.
HUMIDITY SETTINGS
HUMIDIFY
DEHUMIDIFY
|
Use up/down arrows to change the humidity setpoint (between 45 and
60%); press SAVE.
DEHUM SETPOINT
5O%
DEFAULT (5O%)
45%
OFF if OFF selected in installer settings for both humidify and dehu-
midify, this message appears when HUMIDITY SETTING is pressed:
HUMIDITY MODES OFF
If OFF is selected by the installer settings for DEHUMIDIFY but HU-
MIDIFY is on, the humidification menu appears (this setpoint adjust has
NO effect on dehumidification):
HUM SETPOINT
45%
DEFAULT (45%)
4O%
®
Humiditrol
Enhanced Dehumidification Acces-
sory (EDA)
®
If a Humiditrol
EDA is present in the equipment at hand, then the Com-
fortSenset Model L7742U thermostat must be configured to properly
|
operate the Humiditrol
®
Humiditrol
EDA operation flowchart):
From the OPTIONS screen, select INSTALLER SETTINGS. Scroll to
HUMIDITY SETTINGS and press ENTER; select DEHUMIDIFY.
HUMIDITY SETTINGS
HUMIDIFY
DEHUMIDIFY
|
Scroll to HUMIDITROL and press ENTER.
DEHUM MODE SETTING
HUMIDITROL
Set the dehumidification setpoint; then press SAVE.
DEHUM SETPOINT
DEFAULT (5O%)
Check the HUMIDITY SETTINGS in user settings to confirm that the
user has control of the dehumidification setting.
The ComfortSenset Model L7742U thermostat is now configured to
operate the Humiditrol
®
NOTE − Humiditrol
EDA operation requires use of an outdoor sensor.
If sensor is not connected and Humiditrol
DOOR SENSOR REQUIRED" is displayed in the information display.
ComfortSenset Model L7742U Touch Screen 7−Day Programmable Thermostat
Page 21
®
EDA as follows (see Figure 16 [Page 32] for the
|
50%
45%
®
accessory.
®
EDA is enabled, OUT-

Hide quick links: