INSTALLATION INSTRUCTIONS
E1998 Lennox Industries Inc.
Dallas, Texas
INSTALLATION INSTRUCTIONS FOR LOW AMBIENT CONTROL KIT LB-57113BM (27J00)
USED WITH SINGLE-COMPRESSOR HEAT PUMP UNITS
SHIPPING AND PACKING LIST
Package 1 of 1 contains:
1- Low ambient pressure switch assembly (S11)
1- 36" (914 mm) length of 1/4" (6.35 mm) copper tube
with flare nuts
1- Relay
1- 20 Foot length of wire
4- 20" Lengths of wire
1- Bag assembly each containing:
8-Wire nuts
2-Saddle valves
4-#10-16 X 5/8" S.D.S.T. screws
1-Schrader depressor tee with seal cap
APPLICATION
The low ambient pressure switch (S11) cycles the
outdoor fan while allowing compressor operation in the
cooling cycle. This intermittent fan operation results in
a high evaporating temperature which allows the
system to operate without icing the evaporator coil and
losing capacity. This kit is designed for use in ambient
temperatures no lower than 30°F.
Lennox recommends a belly-band style crankcase heater
(P-8-8852, 240v, 45w) be added to compressors which
do not have one. A freezestat (LB-62858CA) should also
be added to any system using a low ambient kit.
NOTE - Do not use this low ambient kit on units with
capillary tube metering devices. Install an expansion
valve metering device if using this kit.
KITS COMMON TO HEATING
®
AND COOLING EQUIPMENT
502,818M
11/98
Supersedes 3/96
Page 1
LOW AMBIENT CONTROL KIT
INSTALLATION
A-Pressure Switch Assembly
1- Disconnect power to unit.
2- Remove compressor compartment access panel.
3- Install valve depressor tee discharge line gauge port.
4- Install pressure switch in compressor compartment
with screws provided. Switch should be installed in a
vertical position higher than mid-point of compressor.
See figure 1.
TYPICAL INSTALLATION
SHOCK
LOOP
FIGURE 1
5- Connect copper line to low ambient pressure
switch and open side of depressor tee (provided).
Provide a shock loop in copper tubing to prevent
breakage from vibration. Tighten connections.
Depressor tee port with valve core is used as
service port. If necessary, valve core can be moved
to other leg of tee.
Litho U.S.A.
S11 LOW AMBIENT
PRESSURE SWITCH
COMPRESSOR
HIGH
PRESSURE
SWITCH
DISCHARGE
LINE
S24 LOSS
OF CHARGE
SWITCH
VALVE
DEPRESSOR
TEE

Advertisement

loading

Summary of Contents for Lennox LB57113BM

  • Page 1 This kit is designed for use in ambient S24 LOSS temperatures no lower than 30°F. OF CHARGE Lennox recommends a belly-band style crankcase heater SWITCH (P-8-8852, 240v, 45w) be added to compressors which VALVE do not have one. A freezestat (LB-62858CA) should also DEPRESSOR be added to any system using a low ambient kit.
  • Page 2 B-Low Ambient Pressure Switch Setting (S11) LOW AMBIENT PRESSURE SWITCH S11 DETAIL One of two types of pressure switches are provided. The Ranco switch has one square and one round adjustment RANCO MODEL knob and the Alco switch has two square adjustment knobs.
  • Page 3 Low ambient kits are shown with optional arrows on unit WIRING wiring diagrams. If unit wiring diagram is not available or Low ambient pressure switch S11 is wired in series with does not show the low ambient kit, refer to appropriate outdoor fan relay or compressor contactor (single-stage wiring diagram in figures 3 through 13 for wiring or speed units).
  • Page 4 TYPICAL SINGLE-COMPRESSOR HEAT PUMP UNIT WIRING DIAGRAM (S11 LOW AMBIENT CONTROL SWITCHES OUTDOOR FAN DIRECTLY) SEE PICTORIAL FIGURE 3 FIGURE 4 Page 4...
  • Page 5 S11 LOW AMBIENT PRESSURE CONTROL SWITCHES OUTDOOR FAN(S) THROUGH A RELAY OR CONTACTOR (PILOT CIRCUIT) HP17-953, 1353 TWO-SPEED FIELD WIRING FACTORY WIRING TO K70-1 PIN 4 A4 (R1) 24 V POWER DEFROST REVERSING RELAY VALVE RELAY REMOVE THIS WIRE LOW AMBIENT PRESSURE SWITCH K58 LOW AMBIENT...
  • Page 6 TYPICAL SINGLE-COMPRESSOR HEAT PUMP UNIT WIRING DIAGRAM (S11 LOW AMBIENT CONTROL SWITCHES OUTDOOR FAN THROUGH A RELAY OR CONTACTOR (PILOT CIRCUIT) SEE PICTORIAL FIGURE 5 FIGURE 6 Page 6...
  • Page 7 TYPICAL SINGLE-COMPRESSOR PACKAGED HEAT PUMP UNIT WIRING DIAGRAM (S11 LOW AMBIENT CONTROL SWITCHES OUTDOOR FAN DIRECTLY) CHP16-2 TO 5 TON UNITS REMOVE THIS WIRE COMPRESSOR CONDENSER 1 CONTACTOR K58 LOW FAN RELAY AMBIENT RELAY COMPRESSOR 1 AMBIENT PRESSURE SWITCH COMP 1 OUTDOOR FAN MOTOR 1 REVERSING...
  • Page 8 TYPICAL SINGLE-COMPRESSOR PACKAGED HEAT PUMP UNIT WIRING DIAGRAM (S11 LOW AMBIENT CONTROL SWITCHES OUTDOOR FAN DIRECTLY) CHP16-2 TO 5 TON UNITS SEE PICTORIAL FIGURE 7 FIGURE 9 Page 8...
  • Page 9: Single Phase

    S11 LOW AMBIENT CONTROL SWITCHES OUTDOOR FAN DIRECTLY (LINE VOLTAGE) SINGLE PHASE K1-1 TERMINAL T1 K31 TERMINAL 5 K69 TERMINAL L1 COMPRESSOR TERMINAL BOX TERMINAL 1 DEFROST RELAY REMOVE THIS WIRE OUTDOOR AMBIENT FAN MOTOR PRESSURE SWITCH TO K31 TERMINAL 4 K58 LOW AMBIENT RELAY...
  • Page 10 TYPICAL SINGLE-COMPRESSOR, TWO-STAGE, SINGLE PHASE HEAT PUMP UNIT WIRING DIAGRAM (S11 Low Ambient Control Switches Outdoor Fan Directly) SEE PICTORAL FIGURE 10 FIGURE 11 Page 10...
  • Page 11: Three Phase

    S11 LOW AMBIENT CONTROL SWITCHES OUTDOOR FAN DIRECTLY (LINE VOLTAGE) THREE PHASE AMBIENT PRESSURE DEFROST REMOVE THIS SWITCH RELAY WIRE TO K10-1 TERMINAL 3 OUTDOOR K58 LOW FAN MOTOR AMBIENT RELAY TO 24V COM REVERSING VALVE FIELD WIRING FACTORY WIRING SEE SCHEMATIC FIGURE 13 FIGURE 12 Page 11...
  • Page 12 TYPICAL SINGLE-COMPRESSOR, TWO-STAGE, THREE PHASE HEAT PUMP UNIT WIRING DIAGRAM (S11 Low Ambient Control Switches Outdoor Fan Directly) SEE PICTORAL FIGURE 12 FIGURE 13 Page 12...