WHEN 2−STAGE HEAT IS USED, T'STAT IS
CONFIGURED FOR 2−STAGE HEAT, CONNECT 2ND
STAGE HEAT BULB TO TERMINAL W2 & REMOVE
JUMPER BETWEEN R & W2.
CUT ON−BOARD LINK (CLIPPABLE CONNECTION)
FROM DS TO R (W914) WHEN DEHUMIDIFICATION
OR HARMONY CONTROL IS USED.
DO NOT CUT ON−BOARD LINK (CLIPPABLE
CONNECTION) FROM R TO O (W951). IT IS USED
FOR CONDENSING UNIT APPLICATIONS.
REMOVE R TO O JUMPER IN HEAT PUMP
APPLICATIONS.
REMOVE DS TO Y1 JUMPER WHEN
DEHUMIDIFICA TION D TERMINAL IS USED.
OUTDOOR SENSOR FOR OUTDOOR TEMP. DISPLAY,
DEW POINT CONTROL, HEAT PUMP BALANCE
POINTS & DUAL FUEL BALANCE POINTS.
RED WIRE TO OUTDOOR CONDENSING UNIT USED
ONLY FOR UNITS WITH LSOM & FOR ALL HEAT
PUMPS.
BROWN WIRE USED ONLY ON UNITS WITH LSOM.
FOR HUMIDIFIER, 48G95 (OR EQUIVALENT)
ISOLATION RELAY REQUIRED (COIL 24VAC, 5VA
MAX.). CAN BE USED WITH ALL T'STAT
APPLICATIONS.
CUT ON−BOARD LINK (CLIPPABLE CONNECTION)
FROM Y1 TO Y2 (W915) FOR 2−STAGE COOLING.
K183 DEHUMIDIFICATION RELAY KIT (26W62)
REQUIRED WHEN USING D TO DS TERMINALS WITH
CB(X)27 UNITS.
NOTE: NOT ALL UN-
USED TERMINALS ARE
SHOWN ON T'STAT
DIAGRAMS.
Figure 19. Thermostat Wiring Diagrams
Page 35
ComfortSenset Model L7742U Touch Screen 7−Day Programmable Thermostat
DUAL FUEL
FURNACE SETUP
CUT ON−BOARD LINK
(CLIPPABLE CONNECTION)
FROM R TO O (W951).
CUT ON−BOARD LINK
(CLIPPABLE CONNECTION)
FROM R TO DS (W914).
WITH DEFROST
TEMPERING, SET W2 TO