Safety Information; Summary Of Installation Cautions And Warnings - Drolet Escape 1400 Installation And Operation Manual

Hide thumbs Also See for Escape 1400:
Table of Contents

Advertisement

Escape 1400 Insert Installation and Operation Manual
3. CHIMNEY CAPS:
Mesh type chimney caps must have provision for regular cleaning, or the mesh should
be removed to eliminate the potential of plugging.
4. ADJACENT COMBUSTIBLES:
The fireplace should be inspected to make sure that there is adequate clearance to
combustibles, both exposed combustibles to the top, side, and front as well as
concealed combustibles, in the chimney and mantle area. Your local inspector should
have information on whether older fireplaces are of adequate construction.
5. OPENING SIZE:
Refer to Section 8.5 Minimum masonry opening for suitable size fireplace openings.

7 Safety Information

7.1 Summary of Installation Cautions and Warnings

THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE
APPLIANCE ALWAYS OVERRIDES THE INFORMATION PUBLISHED, IN ANY
OTHER MEDIA (OWNER'S MANUAL, CATALOGUES, FLYERS, MAGAZINES
AND/OR WEB SITES).
MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES OR
MODIFYING COMPONENTS MAY RESULT IN HAZARDOUS CONDTIONS. WHERE
ANY SUCH CHANGES ARE PLANNED, STOVE BUILDER INTERNATIONAL INC.
SHOULD BE CONTACTED IN ADVANCE.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN
WRITING BY THE TESTING AUTHORITY VIOLATES CSA B365 (CANADA), AND
ANSI NFPA 211 (USA).
CONNECT THIS INSERT ONLY TO A LISTED STAINLESS STEEL CHIMNEY LINER
FOR USE WITH SOLID FUEL.
IF REQUIRED, A SUPPLY OF COMBUSTION AIR SHALL BE PROVIDED TO THE
ROOM.
DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION
DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATION.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER
APPLIANCE.
28