Drolet VISION XL Operation And Installation Instructions Manual
Drolet VISION XL Operation And Installation Instructions Manual

Drolet VISION XL Operation And Installation Instructions Manual

Zero clearance

Advertisement

"VISION XL"
ZERO CLEARANCE
DROLET STOVES AND FIREPLACES INC.
A-45033
REV. 09/96
_____________________________________________________________________________
DROLET "VISION XL" zero clearance fireplace

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VISION XL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Drolet VISION XL

  • Page 1 "VISION XL" ZERO CLEARANCE DROLET STOVES AND FIREPLACES INC. A-45033 REV. 09/96 _____________________________________________________________________________ DROLET “VISION XL” zero clearance fireplace...
  • Page 2 OPERATION AND INSTALLATION INSTRUCTIONS • Read instructions before assembling and keep for future reference. • Consult local authorities for special standards applicable for the necessary licenses. • Install as instructed by the manufacturer and in compliance with the National Building Code. INCLUDED WITH UNIT: 1 - Insulated fireplace 6 - Refractory stones for combustion chamber...
  • Page 3: Installation Of Unit

    INSTALLATION OF UNIT • Locate your unit in the room. • The fireplace can be installed directly on the floor or raised on a combustible structure. (plan 1)
  • Page 4 (plan 2)
  • Page 5 (plan of the pipe)
  • Page 6 ATTENTION The fireplace will lay on a rigid surface. Every single part that make up the base will lay on the surface to uniformly spread the weight. Failure to follow the proceeding recommendations could result in damages to the unit. INSTALLATION OF EXTERIOR AIR INLET •...
  • Page 7: Chimney Installation

    • Use the anchor plate specific to the chimney model used and fix on top of the unit with 4 metal screws. • When a 7” chimney is installed on the “0” clearance Vision XL it is necessary to use the stainless steel chimney adaptor plate supplied with the unit.
  • Page 8: Notes On Installation

    INSTALLATION OF HOT AIR OUTLET (See drawing) • Use extensible and flexible insulated pipe supplied with your unit. • Stretch extensible pipe to its maximum length, 10 feet. Bend to form a 90 elbow and cut at desired length. • Insert pipe into its insulation covering. •...
  • Page 9 When doors are opened or removed, it works like a standard fireplace. However, more heat is saved from the double wall construction of the Vision XL. This mode of operation requires completely open air intake controls, if you have installed the outside air inlet. Doing so, you will allow outside air in the combustion chamber, reducing the risk if negative pressure.
  • Page 10 Only wood with a moisture content below 20% can be used as fuel. The Vision XL is not designed for fire-dogs or other accessories to support or contain fuel. When first using your fireplace, do not over heat to avoid thermal shock that could damage paint and refractory stones.
  • Page 11: Door Glass

    CREOSOTE; Formation and need for removal When wood is burning slowly, it produces tar and other organic vapors, which combined with expelled moisture generates creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, creosote makes an extremely hot fire.
  • Page 12: Disposal Of Ashes

    Do not clean gold doors with materials which may scratch or otherwise damage them. Do not use abrasive cleaners, nor chrome or silver cleaners because they can be corrosive. Household cleaners are adequate. TYPE OF GASKET Gaskets must be replaced when wear appears. The replacement parts are available at your dealer. DISPOSAL OF ASHES Ashes should be placed in a metal container with a tight-fitting lid.
  • Page 13 _____________________________________________________________________________ LIMITED 25 YEARS GUARANTEE DROLET STOVES & FIREPLACES INC. hereby guarantees the quality of its “ Vision XL “ controlled combustion fireplace which bears listed approval of Warnock Hersey under ULC standards. The product shall be delivered to the buyer in good condition and the latter shall inform the vendor immediately of any defect in the product.
  • Page 14 DROLET STOVES & FIREPLACES INC. 1700, Leon-Harmel Quebec, Qc (Canada) G1N 4R9...