4-3. Maintenance Menu
4-3-6. OTHERS Check

4-3-6. OTHERS Check ([F9] : OTHERS CHECK)

Overview
N V R A M
C T L
M E M O R Y
C H E C K
R S 2 3 2 C
S T A T U S
M - H E A D
R O O M
H O U R S
P A R A - I
M E T E R
S E T U P
n Actual typefaces differ from the ones shown in diagrams in this manual. Also, the content of diagram
are only one example of many.
[F1] (NVRAM CTL) Key :
Saves the cassette up data (function setup) of BKDW-509 into NVRAM, or resets it
to the set up value at shipping from factory.
[F3] (RS232C STATUS) Key :
Indicates the status of RS-232C. Also performs set up the flow control and the
communication speeds necessary in ISR.
n This is the menu for ISR. ISR (Interactive Status Reporting system) means the system to perform
monitoring of operation and self-diagnostics of various broadcast devices from a PC using BZI-500/
501 (ISR software).
[F4] (M-HEAD ROOM) Key :
Performs set up the head room of audio level meter.
[F5] (HOURS METER) Key :
Performs indication and reset of the resettable hours meters and the thread counter of
this unit.
[F6] (PARA-I SETUP) Key :
This is the menu for optional BKDW-509. Used to change the set up data (function
set up of input pins of the parallel interface) of BKDW-509. Also indicates the logic
level of the input pins.
[F7] (PARA-O SETUP) Key :
This is the menu for optional BKDW-509. Used to change the set up data (function
set up of output pins of the parallel interface) of BKDW-509. Also indicates the
logic level of the output pins.
[F9] (SYSTEM MENU) Key :
Changes the operating mode of this unit.
[F10] (EXIT) Key :
Exits OTHERS CHECK menu, and returns to MAINTENANCE menu.
4-46
CH.COND
O THERS CHK
TC R 00 :00:00:00
OTH ERS CHE CK
P A R A - O
S Y S T E M
E X I T
S E T U P
M E N U
HDW-F500E MMP1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents