Programming
OUTPUTS
Left Valve
• Left Valve Test
• L. Valve Calib
'' ''
'' ''
Left Valve display is only for CBS-2132- dual station brewer. CBS-2131 displays RIGHT SIDE only
Right Valve
• Right Valve Test
• R. Valve Calib
'' ''
'' ''
Fill Valve
• Fill Valve Test
Heater
• Heater Test
Screen
• Screen Contrast
• S. Brightness
1) Measure the flow rate
-Enter programming mode, scroll left to "OUTPUTS"
-Scroll down to "Left(or)Right Valve Test"
-Place 2qt./2 l measuring container under empty brewbasket. One good way to measure is to weigh the test
water. Use a scale for at least 2 kg/5lb
-Press To Test the Brew Valve.
place for the entire minute.
Measure the flow and hold the number
2)Calibrate the flow rate
-Enter the number measured from the one minute flow rate test (above) into the Calibration Slider
-After entering the measured volume, exit PROGRAMMING and return to the normal screens
By entering the new flow rate number into the brewer, the software automatically corrects the valve flow discrepancy
1. The CBS-2130 coffee brewers include a hot water convenience tap for single cup beverage
purposes.
2. Single use delivery volume should not exceed maximum 16fl.oz/473cc.
3. Water dispensed from this faucet is very hot, up to 205°F/96°C
Factory set
Items
Default
(Press to test)
Calibrate
*Flow Rate
(Press to test)
Calibrate
*Flow Rate
(Press to test)
(Press to test)
Contrast
Brightness
*How to calibrate the flow rate
Set the flow rate to compensate for over or under potting
!
Keep finger on touchpad for one minute. It is important to keep finger in

Hot water convenience tap

Programming Range
(display)
TEST
Press To Test
1540 ml p m
|_________[]________|
500
TEST
Press To Test
1540 ml p m
|_________[]________|
500
TEST
Press To Test
TEST
Press To Test
8
|____________[]____|
1
8
|____________[]____|
1
15
Notes
Runs valve to verify
flow. Have container
under brewbasket!
Factory or service use
for flow rate
1800
Runs Valve to verify
flow. Have container
under brewbasket!
Factory or service use
for flow rate
1800
Operates fill valve.
Have container under
both brewbaskets!
Energizes Heater(s)
Use for servicing.
10
10