Guide to a Successful Installation

If not installed correctly by qualified personnel, the brewer will not operate properly and damage may
result.
Damages resulting from improper installation are not covered by the warranty, and will void the warranty.
Here are the key points to consider before installation:
Electrical:
All FETCO brewers require an electrical ground wire. Installation without grounding is
dangerous.
Verify voltages, polarity, circuits, and circuit breaker access before attaching equipment.
The electrical diagram is located in the Users Guide and online at www.fetco.com.
The installation must comply with applicable federal, state, and local codes having jurisdiction at
your location. Check with your local inspectors to determine what codes will apply.
Plumbing:
All installations must comply with applicable federal, state, or local plumbing codes.
An inline water filter is highly recommended. It should be installed after a water shutoff valve and
in a position to facilitate filter replacement.
The water line and newly installed filter cartage must be flushed thoroughly prior to connecting it to
the brewer to prevent debris from contaminating the machine.
Verify that the water line will provide a flow rate of at least 1½gpm/ (5.7lpm) per minute and water
pressure is between 20-75 psig (138-517kPa) before making any connections.
Install a backflow prevention device if required. Many municipalities require a recognized backflow
preventer. Usable on all hot beverage and cold beverage equipment is a WATTS® SD-2 or SD-3.
These spring loaded double check valve models are accepted by most zoning authorities.
The check valve should be as close to the water supply inlet of the beverage equipment as possible.
General:
Utilize only qualified beverage equipment service technicians for installation.
A Service Company Directory is available at www.fetco.com.
Leveling legs, if installed, are to be
adjusted for leveling the brewer only.
Do not use for height adjustment, or extend
them higher than necessary.

Installation

(For Qualified Service Technicians Only)
WARNING
21
Utility slide
on back
of brewer
Power
Switch
Electrical
Connection
Tank Drain
Water
Supply
Connection